Kidde KN-COB-B-LPM Manuel D’Utilisation

Page de 10
Whenever the alarm is operating, the green Power LED flashes every 30 
seconds to indicate the unit is monitoring for CO. If the alarm senses 
dangerous levels of CO, the red Alarm LED will flash and the alarm will 
emit an audible alarm pattern. 
6. Model KN-COPP-B-LPM (with digital display)  
  Operating Characteristics
5. Model KN-COB-B-LPM Operating Characteristics
Operating and Alarm Characteristics
Function 
LED Display 
Alarm Sound  Unit Status  
Recommendation
Normal
Operation
Green LED 
flashes every 30 
seconds
None
Normal DC 
operation (sensing 
no CO) and with  
good batteries
None
Carbon 
monoxide 
alarm
Red LED flashes 
with beeps. 
4 quick beeps, 
5 seconds 
silence, 
repeating
Alarm condition.
Dangerous con-
centrations of CO 
detected
Refer to “What to 
do When the Alarm 
Sounds” (inside front 
cover)
Low 
battery
Red LED flashes 
every 60 seconds
One quick 
beep every 
60 seconds
Batteries need to be 
replaced
Replace all three AA 
batteries 
Error / 
service 
alarm
Red LED flashes 
every 30 seconds
One quick 
beep every 
30 seconds
Unit is in error 
condition
Error
Red LED 
constantly on
Constant 
alarm
Very low battery or 
unit malfunction
Replace battery. 
If condition continues, 
unit has malfunc-
tioned. Replace 
immediately. Unit will 
not respond to CO
Normal 
Test/Reset 
function
Red LED flashes 
with beeps.
4 quick beeps, 
5 seconds 
silence, 
repeated once
Normal operation 
when Test/Reset 
button is pressed
CO not detected. 
Alarm for test pur-
poses only
End of 
unit life 
indicator
Red LED flashes  
two times 
every 30 seconds
Two quick 
beeps every 
30 seconds
End of unit life
Replace unit imme-
diately. Unit will not 
respond to to CO
The following table illustrates the possible digital displays, describes the 
audible alarm patterns, and the recommended actions to take.
6. Model KN-COPP-B-LPM (with digital display)  
  Operating Characteristics
When the unit is first powered up, the green Operate LED flashes  
once every 30 seconds and the digital display will show three “eights” 
– indicating the alarm is in the start-up mode. The three “eights” will 
remain for approximately 30 seconds. Then, the alarm will display “0” 
and begin monitoring the air for CO and will continue to do so as long 
as it receives power.
This alarm will display a “0” if CO concentrations between 0 and 30 
PPM have been detected within the last 15 seconds.
Operating and Alarm Characteristics
LCD Display Shows 
Alarm Sound 
Unit Status  
Recommendation
A steady display of 
CO concentration 
from 30-999. Red 
LED flashes with beep
4 quick beeps,
5 secs. silence,
repeating 
Alarm condition. 
Dangerous 
concentrations of 
CO detected
Refer to “What to 
do When the Alarm 
Sounds” (inside front 
cover)
Brief “888” for 
approximately 30 
seconds
None
 
Self test when first 
powered up
None – CO has 
not been detected. 
Numbers shown for 
test purpose only
A random number 
is displayed – 
between approxi-
mately 150 and 300
4 quick beeps,
5 seconds 
silence,
repeated once 
Test/Reset button is 
pressed
None – CO has 
not been detected. 
Numbers shown for 
test purpose only
Steady “0” displayed, 
dot flashing every 5 
seconds, Green LED  
               flashes every 30 secs.
None
Normal DC 
operation with 
good batteries 
(sensing no CO)
None
“Lb” flashes alter-
nately with any 
number, Red LED 
flashes every 60 seconds. 
One quick beep 
every 60 seconds
Batteries need to 
be replaced
Replace all three AA 
batteries immediately
“Err” displayed
One quick beep 
every 30 seconds
Unit is Error con-
dition
Replace batteries. 
If “Err” (or blank 
display) continues, 
unit has malfunc-
tioned. Replace 
immediately. Unit will 
not respond CO
Display is blank
Constant alarm
Unit malfunction
Number from 
11-999 displayed. 
None
Peak Level Memory 
activated. Highest 
concentration of 
CO detected is 
displayed
Refer to following 
section for informa-
tion regarding Peak 
Level Memory
“End” displayed.  
Red LED flashes 
two times  
every 30 seconds
Two quick  
beeps every  
30 seconds
End of unit life
Replace unit imme-
diately. Unit will not 
respond to CO.
The problems listed above are under normal operating conditions. Other 
“Err” conditions could exist. If you should have any questions regarding 
display conditions, call our Consumer Hotline.