Daniel 3818 LNG Liquid Ultrasonic Meter Installation Manual
Section 1: Introduction
3-9000-771 Rev A
May 2012
Pre-installation considerations
 11
1.7
Pre-installation considerations
Pipeline equipment code compliance, ANSI, ASME, etc.
Proper Inlet/outlet meter tube piping for reasonable stable flow to the settling chamber 
(first meter tube spool upstream of the meter).
Electrical safety compliance; UL, ULC, ATEX, IECEx etc.
Civil and structural good practices compliance
Contractual agreements or governmental compliance (or both)
In-situ performance test procedures
Field tested advanced meter health and flow dynamics diagnostics 
Data collection and retention procedures
All piping and the meter body must be sufficiently insulated for bubble-free flow 
through the meter
1.8
Safety
The Daniel 3818 LNG Liquid Ultrasonic Flow Meter is suitable for use in U.L. Class 1, Division 1, 
Group C and D hazardous locations.
EXPLOSION OR FIRE HAZARD
Read and follow the instructions below:
Conduit runs must have a sealing fitting within 457mm (18 inches) of the enclosure to reduce the 
risk of an explosion or a fire. 
During operation, keep covers tightly closed. DO NOT  open the transmitter electronics 
enclosures when an explosive  atmosphere may be present.
During equipment maintenance, disconnect power before opening the transmitter electronics 
enclosures. Clean cover joints before replacing. 
DO NOT substitute meter components. Substituting components  may compromise the intrinsic 
safety of the device.
Failure to follow these safety instructions may result in severe injury to personnel or cause damage to
the equipment.