Venting
991 DV GS
Cap (High Wind)
980 DV GS
Cap (Low Profi le)
923GK DV GS 
Chimney Liner Kit
930 DV GS
Extended Cap
923F DV GS
Appliance
Flex Connector
2150 DV GS
Flex Connector
7.3 Vent Installation
IMPORTANT: This appliance’s venting system is room sealed, which means that there should be no 
provision to allow room air to be used in the combustion process.
Note: Use only 3” fl ex venting materials approved for masonry installations.
Planning Your Vent Installation
This type of direct vent system may only terminate in the following way: 
Vertical termination using a Dura-Vent 
3” adapter and cap (see Vent parts list). 
There are limitations to the vertical and/or 
horizontal lengths (see page 11 for venting 
chart).
When calculating the length of the vent 
pipe from the outlet of the appliance to 
termination, allow for any offsets in the 
chase and suffi cient vertical height above 
the roof.
Apply RTV sealant to the appliance’s 
vent pipe and slide over the air intake 
and exhaust pipes.
Secure using the 8 self-tapping screws 
provided (4 per fl ex pipe).
Slide the unit into the opening, taking 
care not to damage the liner (allow 
enough slack for fi nal surround 
assembly).
At the top of the chimney, slide the 
connector plate over the 2 fl ex liners.
Attach the termination cap to the fl ex 
pipes using the 8 screws provided.
Seal the connector plate to the chimney 
(fi re cement).
1.
2.
3.
4.
5.
6.
WARNING: Failure to position the parts in accordance with these 
diagrams or failure to use only parts specifi cally approved with 
this appliance may result in property damage or personal injury.
Note: Inspect vent connection before 
installing the trim surrounds.
Typical components used in shown example.