Napoleon Fireplaces EF30G Manuel D’Utilisation

Page de 20
W415-0760 / 12.19.08
20
8.0 troubleshooting
!
WARNING
Turn off the fireplace completely and let cool before servicing. Only a qualified service person should 
service and repair this electric fireplace.
SYMPTOM
Dim or no flame.
Ember bed is not 
glowing or dimming.
Fireplace turns off 
and will not turn on.
Fireplace will not 
come on when switch 
is flipped to ON.
Remote control does 
not work.
No warm air is 
coming out of the 
fireplace.
PROBLEM
TEST SOLUTION
Bulb(s) are burnt out.
Bulb(s) are burnt out.
Fireplace has overheated and 
safety device has caused the 
termal switch to disconnect.
House circuit breaker has tripped.
Fireplace is not plugged into an 
electrical outlet.
Fireplace has overheated and   
safety device has caused the 
thermal switch to disconnect.
Low batteries.
Room temperature is higher 
than the fireplace setting (if it is 
set to LO or MED).
-   Inspect the bulbs inside the flame generation cylinder 
    drum and replace them if necessary.
-   Inspect the ember bed bulbs and replace them if necessary.
-   Unplug the unit, allow fireplace to cool for 10 minutes, then 
    plug it back in.
-   Reset house circuit breaker.
-   Check plug and plug it in.
-   Unplug the unit, allow fireplace to cool for 10 minutes, then 
    plug it back in.
-   Replace AA batteries in remote transmitter.
-   Set fireplace to a higher temperature setting (MED or HI).
tp - trouble shooting Warning
tp - trouble shooting_electric