Regency P33-NG4 Manuel D’Utilisation

Page de 52
Regency
®
 P33-4 Zero Clearance Direct Vent Gas Fireplace
39
INSTALLING THE OPTIONAL FAN
120 Volt AC power is needed for the fan switch 
and blower. The fan can be hard wired if desired. 
The  receptacle box should be installed  on  the 
left hand side of the unit by a qualifi ed electrician. 
The neutral (wider) slot of the polarized 
receptacle should be at the top.
Unit must be grounded at all times. Do 
not cut the ground terminal off under any 
circumstances.
1)  Shut the power off.
2)  Remove the standard fl ush door and the 
optional bay door, if installed. Open the 
bottom louver door. 
3)  Loosen the 2 screws holding the Burner 
ON/OFF switch and bracket to the bottom 
louver and lift the assembly out.
4)  Turn the fan base on its side (with the base 
facing towards you) and then slide the fan 
in towards the rear of the unit. Turn the fan 
upright and slip it over the two mounting 
studs. Take care not to damage the insulation 
on the fan base. Ensure that the fan blades 
do not rub against the valve tubing. 
Diagram 1.
5)  Connect fan ground cable to ground lug. 
Refer to wiring diagram.
6)   Slide the  thermodisc/cover assembly  into 
the bracket clip on the underside of the 
fi rebox. Check that no wire will touch the 
hot surfaces. Diagram 2.
7)  Attach the Fan control box to the  Burner 
ON/OFF control box. Diagram 3.
11)  Attach the two control boxes to the bottom 
louver and tighten the 2 screws on the left 
side and 1 screw on the right side.
Secure left side with 2 screws.
Secure right side with one screw.
Secure the 2 boxes together 
with one screw.
Hold control box assembly in place and 
mark the position of the right side slot
Diagram 1
Diagram 2
Diagram 3: Use the clip & hook on the side of 
the control boxes to join them together.
8)  Secure the two boxes together with one 
screw.
9)  Position the control box assembly on the 
bottom louver and mark the position of the 
slot on the right side bracket.
Push hold-down clip onto inside louver  
and  press  tab until  it is at 90
o
 to louver. 
10) Remove the control box assembly and push 
the hold-down clip onto the louver. Bend the 
tab until it is at 90
o
 to the louver.
12) Secure the fan wires and power cord by 
attaching one of the adhesive backed 
wire holder clips (Part #910-199) onto 
the Fireplace base. Use the second clip 
to bundle up the wires approximately 4" 
from the control box. Ensure that there is 
no interference with the wires when the 
louver is closed and that no wire will touch 
the hot metal surfaces or sharp edges.
13)  Plug the fan power cord into the rear end of 
the receptacle box to provide the maximum 
clearance from the louvers.
TO REMOVE THE FAN
1)  Shut the power off.
2)  Reverse the above instructions.
Note:   The bearings are lubricated for life. 
Do not lubricate them. Make sure 
you vacuum the fan area on a regular 
basis.
IMPORTANT:
These fans collect a lot of dust from within 
your home. Ensure you maintain these fan 
motors on a regular basis by vacuuming 
out the fan blades and housing using a 
soft brush nozzle.
INSTALLATION