Regency P121LC-NG Manuel D’Utilisation

Page de 40
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
13
FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS
Regency Direct Vent System (Flex) Horizontal Terminations Only
These flueing systems, in combination with the P121/P121LC/P121RC/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct flue
heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram
on page 12.
Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121/P121LC/P121RC/
P131  with  a  maximum  run  of  2  feet.
1) 6-7/8" dia. flexible liner (2 ft. length)
2) 4" dia. flexible liner (2 ft. length)
3) spring  spacers  (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws  (12)
7) tube of Mill Pac (1)
8) plated  screws  (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner  sections  should  be  continuous  without  any  joints  or  seams.
2) Only  Flex  pipe  purchased  from  Regency  may  be  used  for  Flex  installations.
3) Regency  Direct  Vent  System  (Flex)  is  only  approved  for  horizontal  terminations.
INSTALLATION