Regency P121 Manuel D’Utilisation

Page de 48
Regency
®
 P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace
18
INSTALLATION 
Diagram 3
Horizontal Venting with Two (2) 90
o
 Elbows
Horizontal Venting with Two (2) 90
o
 Elbows
Horizontal Venting with Three (3) 90
o
 Elbows
Horizontal Venting with Three (3) 90
o
 Elbows
Diagram 5
Diagram 4
Diagram 6
 
Option 
 V 
  H 
H1
     A) 
1' (305mm) Minimum 
2' (610mm) Maximum
     B) 
2' (610mm) Minimum 
5' (1.5m) Maximum
     C) 
3' (914mm) Minimum 
8' (2.4m) Maximum
     D) 
4' (1.22m) Minimum 
11' (3.35m) Maximum
     E) 
5' (1.5m) Minimum 
14' (4.27m) Maximum
     F) 
6' (1.86m) Minimum 
15' (4.5m) Maximum
With the above options, maximum total pipe length if 37 feet 
with minimum of 6 feet total vertical and maximum 15 feet total 
horizontal.
Please note minimum 1 foot between 90
o
 elbows is required.
 
Option   
          H    
     H + H1 + H2
 
     A) 
2' (610mm) Min.  1' (305mm) Max.  3'(914mm) Max.
 
     B) 
3' (914mm) Min.  3' (914mm) Max.  6' (1.86m) Max.
 
     C) 
4' (1.22mm) Min.  5' (1.5m) Max. 
9' (2.7m) Max.
 
     D) 
5' (1.5m) Min. 
7' (2.13m) Max.  12' (3.6m) Max.
With the above options, maximum total pipe length if 37 feet with minimum 
of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
o
 elbows is required.
Option   
          H    
      H + H1
     A) 
1' (305mm) Min.  1' (305mm) Max.  3'(914mm) Max.
     B) 
2' (610mm) Min.  3' (0.91m) Max.  6' (1.86m) Max.
     C) 
3' (914mm) Min.  5' (1.5m) Max. 
9' (2.7m) Max.
     D) 
5' (1.5m) Min. 
8' (2.4m) Max. 
12' (3.6m) Max.
With the above options, maximum total pipe length if 37 feet with minimum 
of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
o
 elbows is required.
Option 
 V 
V1 
  H 
H1
     A) 
2' (610mm) Minimum 
3' (914mm) Maximum
     B) 
3' (914mm) Minimum 
6' (1.86m) Maximum
     C) 
4' (1.22m) Minimum 
9' (2.7m) Maximum
     D) 
5' (1.5m) Minimum 
12' (3.6m) Maximum
With the above options, maximum total pipe length if 37 feet 
with minimum of 5 feet total vertical and maximum 12 feet total 
horizontal.
Please note minimum 1 foot between 90
o
 elbows is required.