Regency FP90 Manuel D’Utilisation

Page de 40
FPI FP90 Wood Fireplace
33
HEA
TW
A
VE KIT
HEATWAVE KIT (NOT EPA APPROVED)
Diagram 4
4)  Install the variable speed Wall Rheostat (with 
OFF setting) in a convenient location. This 
switch controls the fan operation.
5)  Wire 120V AC service to the Wall Rheostat 
and from the Wall Rheostat to the Fan 
Junction Box. Use wire nuts to secure the 
120V AC wires to the hot and neutral fan 
wires and screw the 120V AC ground wire 
to the Fan Junction Box. See wiring diagram 
below.
6)  Screw the fan junction box to the fan 
housing. 
7)  Screw the Register Adapter Frame and the 
Air Register to the Fan Housing, diagram 4 
below.
 
Oval Air Duct: Attach the round-to-oval 
adaptor to the fi replace starting collar and 
a 6" oval duct (not supplied) to the adaptor. 
Complete the duct run and attach the oval 
duct to the fan housing.
 
Round and Oval Duct: A combination of 
6" round and 6" oval duct can be used in 
the duct run. Oval duct components are 
not supplied but can be purchased from an 
HVAC supplier.
OPERATION
1)  Start the fi replace as per instructions and 
allow it to warm up. 
2)  Turn the Wall Rheostat "ON" and adjust the 
variable speed based upon desired air fl ow 
at the Air Duct Register.
MAINTENANCE
1)  Service and maintain the fi replace as per 
the fi replace installation manual.
2)  Keep the Air Register(s) clean and free of 
any blockage.
 
Note: For new construction only the 
Air Register is required to cover the 
opening.
 
8)  Complete the fi replace installation as per 
fi replace installation manual.
Ground Lug
CAUTION:   Label all wires prior 
to disconnection when servicing 
controls. Wiring errors can 
cause improper and dangerous 
operation.
Caution: Ensure that the wires do 
not touch any hot surfaces and are 
away from sharp edges.
NOTE: The wires (in dotted lines) and 
wire nuts are supplied by others.
IMPORTANT: If the internal blower is installed, it cannot be operated if the Heat Wave air duct kit fan is operating.
WIRING DIAGRAM
Do not cut the ground terminal off 
under any circumstances.
Diagram 3