Regency B36X Manuel D’Utilisation

Page de 64
11
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
FRAMING 
M
N
O
Q
P
R
U V
T
Opening for gas
connection
11" (279mm)
dia. Hole through
wall Vent.
Top Header
Drywall
(or other
facing)
Combustible Facing
S
S
Framing Dimensions
Description
B36X
M
Framing Width
36 - 1/4"(921mm)
N
Framing Height
39 - 3/8" (1000mm)
O (Rear Vent)
Framing Depth - Rear Vent
20 - 3/4" (527mm) 
O  (Top Vent)
Framing Depth - Top Vent
19 - 1/2" (495mm)
P  (Top Vent)
Corner Facing Wall Depth
48 - 5/8" (1235mm)
P  (Rear Vent)
Corner Facing Wall Depth
53" (1346mm) AstroCapXL 
61-1/2" (1562mm) - other approved caps
Q  (Top Vent)
Corner Facing Wall Width
68 - 3/4" (1746mm)
Q  (Rear Vent)
Corner Facing Wall Width
75" (1905mm) AstroCapXL
87" (2209mm) - other approved caps
R (Rear Vent)
Framed Chase Ceiling - Rear
39 - 3/8" (1000mm)
R (Top Vent)
Framed Chase Ceiling - Top
50-1/2" (1282mm)
S  (Rear Vent)
Vent Centerline Height - Rear
26-1/2" (673mm)
S  (Top Vent)
Vent Centerline Height - Top
44-1/4" (1123mm) Rigid 
42-1/8" (1070mm) Flex
T
Gas Connection Height
1-1/2" (38mm)
U
Gas Connection Inset
4-1/8" (105mm)
V
Gas Connection Width
3-1/4" (82mm)
W
Non-Combustible Top Height
0"
Note: If installing the unit into a corner and rear venting - use AstroCapXL 946-623/P to obtain closest clearance.