Regency B36X Manuel D’Utilisation

Page de 64
39
Regency Bellavista™ B36X Gas Fireplace
INSTALLATION
CONVERSION KIT# 556-969 FROM NG TO LP
for B36X using SIT 820 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
1)
 
Shut off the gas supply.
2)
 
Remove the louvers (and Arch screen 
doors if they are installed).
3)
 
Open the fl ush door and remove the 
door.
4)
 
Remove the logs and embers (if already 
installed).
5)
 
Remove the 2 screws holding the Burner 
Assembly to the fi rebox base. Slide the 
Burner Assembly to the left to release it 
from the orifi ce and lift out.
Remove the 2 screws, push Burner Assembly 
to the left and lift out.
9)
 
Unscrew the pilot orifi ce with the allen 
key; then replace with the LPG pilot 
orifi ce, provided in the kit.
7)
 
Remove the wire clip below the pilot cap.
10)
  Remove burner orifi ce with a 1/2" 
wrench. Use another wrench to hold on 
to the elbow behind the orifi ce. Discard 
orifi ce.  
11)
  Reinstall new burner orifi ce LPG 
stamped  #55 and tighten.
Each Kit contains one LP 
Conversion Kit # 556-969 
Conversion Kit Contains:
Qty.   Part # 
Description
  904-575 
Burner Orifi ce #55
1  
904-529  5/32" 
Allen 
Key
1  
918-590  Decal 
"Converted 
  
 
to 
LPG"
  908-528 
Red "LP" label
  910-037 
LP Injector (Pilot Orifi ce)
1          910-073       Spark Generator
1          910-074       Spark Generator Wires
1                               'AA' Battery
1  
918-775  Instruction 
Sheet
8)
 
Pull off the pilot cap to expose the pilot 
orifi ce.
6)
 
Remove the 2 screws securing the rear 
log tray and lift out.
Installation of LP 
Conversion Kit: