Regency Bellavista™ B36X  Gas Fireplace
FAN INSTALLATION
INSTALLATION
Important: 
120 Volt AC power is needed for the 
fan switch and blower.  The  receptacle box will 
be installed  on  the left hand side of the unit and 
will need to be wired by a  qualifi ed electrician 
prior to fan assembly being installed. The neutral 
(wider) slot of the polarized receptacle should 
be at the top.
Unit must be grounded at all times. Do not 
cut the ground terminal off under any 
circumstances.
1)
  Shut the power off.
2)
  Open the bottom louver. Remove the 
      standard fl ush door. 
3)
  Turn the fan base on its side (with the base 
facing towards you) and then slide the fan 
in towards the rear of the unit. Turn the fan 
upright and slip it over the two mounting 
studs. Take care not to damage the insulation 
on the fan base. Ensure that the fan blades 
do not rub against the valve tubing. 
4)
  Connect fan ground cable to ground lug. 
Refer to wiring diagram.
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
Clip
Diagram 6
Diagram 7
TO REMOVE THE FAN
1)
  Shut the power off.
2)
  Reverse the above instructions.
Note:   The bearings are lubricated for life. 
Do not lubricate them. Make sure 
you vacuum the fan area on a regular 
basis.
IMPORTANT:
These fans collect a lot of dust from within 
your home. Ensure you maintain these fan 
motors on a regular basis by vacuuming 
out the fan blades and housing using a soft 
brush nozzle.
Push Fan down
on mounting pins
Electrical
Receptacle
Ground Lug
Plug fan power cord
into
receptacle.
rear
7)
   Slide the the Fan control box
      under the clip on the fl oor of the fi rebox.
       (See Diagram 5) 
8)
   Secure the fan wires and power cord by 
     attaching one of the adhesive backed wire 
holder clips (Part #910-199) onto the stove 
base.  Use the second clip to bundle up 
the wires approximately 4" from the control 
box.  
5)
   Slide the  thermodisc/cover assembly  into 
the bracket clip on the underside of the 
fi rebox. Check that no wire will touch the 
hot surfaces. Diagram 3 and 4.
6)
  Plug the fan power cord into the rear end of 
the receptacle box to provide the maximum 
clearance from the louvers.
    
      
*
Ensure that there is no interference with 
the wires when the louver is closed and that 
no wire will touch the hot metal surfaces or 
sharp edges.