Regency I1100S Manuel D’Utilisation

Page de 20
Regency Wood Insert & Hearth Heater
7
Clearance diagram for installations
INSTALLATION
Side and Top facing is a maximum of 1.5" 
thick. 
Floor protection must non-combustible, insula-
tive material with an R value of 1.1 or greater.
* 
If the hearth extension is fl ush with the fl oor 
(F) it must extend 19.5" in front of the body 
face (E).
Note:  Hearth Extension Width (G) is meas-
ured from edge of fuel door to side 
of hearth.
**   A non-combustible mantel may be in-
stalled at a lower height if the framing 
is made of metal studs covered with a 
non-combustible board.
MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES 
The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below. 
  
Adjacent 
Mantle** 
Top 
Side 
Minimum 
Minimum 
Minimum
          Unit 
Side Wall 
(to Top) 
Facing 
Facing 
Hearth 
Hearth 
Hearth Side
 
 
(to Side) 
 
(to Top) 
(to Side) 
Extension* 
Thickness* 
Extension
  
G
Small Flush
Insert (I1100S)
 15"/380mm 
20"/510mm 
14"/355mm  7.375"/187mm  16"/406mm  1.5"/38mm 
8"/205mm
Large Flush
Insert (I3100L)
 13"/330mm 
19"/480mm 
18"/455mm 
6.5"/165mm  16"/406mm  1.5"/38mm 
8"/205mm
Hearth Heater
   (H2100M) 
10"/255mm 
25"/635 
mm 14"/355mm 8.5"/216mm 
18"/455mm 
1.5"/38mm 6"/152mm
View from  Rear of Insert
OPTIONAL FLUE 
CONNECTOR KIT
The optional Flue Connector Kit (Part # 846-527) 
and the Straight Flue Adaptor (Part  #846-504) 
shown here, may be used to produce a secure 
connection between your fl ue connector and the 
insert collar. Detailed installation instructions are 
included with the kit.
Position the grill on the inside bodyface side and 
fasten using the bolts, washers and nuts provided 
(2 per side) as shown in the diagrams.  
Note: The 
grill has a front and rear, the holes 
on the front side have rounded edges 
and the rear holes have fl at edges.