INSTALLATION REQUIREMENTS
The Town & Country Fireplace installation and venting 
must conform to the current CAN/CGA-B149 installation 
code (in Canada) or the current National Fuel Gas Code, 
ANSI Z223.1 (in the USA), and approved per local codes. 
Only qualifi ed (licensed or trained) personnel should 
install this product.
In the state of Massachusetts, only a licensed Plumber 
and Gas Fitter may install this product.
Fig. # 4
TOP
STANDOFFS
Fig. # 5
Examples of Common Locations
TOP STANDOFFS
The top standoffs are shipped loose inside the fi replace and 
must be installed on top of the fi replace as shown in fi g. #4. 
Do this once the fi replace is on site and in position.
LOCATING THE FIREPLACE
In planning the installation for the fi replace, it is necessary to 
determine where the unit is to be installed, location of vent 
system and where gas supply piping may be plumbed. Vari-
ous installations are possible, such as, into an existing wall, 
a corner, a built-in wall or a wall projection (see Fig. #5). Due 
to high temperatures, do not locate this fi replace in areas of 
high traffi c or near furniture or draperies.
The minimum clearances from the fi replace to combus-
tible surfaces must be adhered to and are shown on Fig. 
# 2 and 3.
CAUTION: When selecting a location, ensure 
that there is adequate room on the right hand 
or left hand side of the fi replace for the control 
box.
SEE FIG #9 FOR
DIMENSIONS