PGS TC36 AR Manuel D’Utilisation

Page de 36
8      36ARB2 
050505-36
1/4"
1"
MAX
HEARTH EXTENSION
While a hearth extension is not required 
for this fi replace, one is recommended 
for aesthetic reasons. The hearth 
extension should be noncombustible 
and must not be any more than 1" 
above the bottom of the fi replace. If 
thicker, fi replace must be raised up 
accordingly.
Caution:  Hearth extensions thicker 
than 1" will interfere with the window 
frame.
CONTROL BOX
The gas control system is housed in a control box remote of 
the fi replace. Flexible conduits attach the control box to the 
fi replace and house all the plumbing and wiring to the burner. 
This unique design allows the control box to be mounted in 
a variety of positions on the right or left side of the fi replace. 
The box can be framed into the front right or left face or the 
right or left sidewall of the fi replace enclosure. As the control 
system is attached at the factory to exit the right side of the 
fi replace, please see "Control Box Relocation" section to move 
the control box to exit the left side.
Caution:  When positioning the control box, do not over 
bend the conduit or use excessive force, as damage may 
occur.
1)  Remove window frame latch tool and set aside.
2)  Remove 4 screws holding control panel in place and 
carefully lift off over the control knobs, being sure not to 
damage wires and connections to the "Pilot Flame" indi-
cator (millivolt control system only). Carefully disconnect 
wires from indicator, and set aside.
3)  Attach control box to framing at predetermined depth, 
allowing room for wall fi nishing material. Side brackets 
can be adjusted for a trim fi t.
4)  Attach control box to framing at predetermined depth, 
allowing room for wall fi nishing material. Side brackets 
can be adjusted for a trim fi t.
5)  Replace door/inner frame assembly and fasten in place.
Note:  Gas supply plumbing must be completed and the 
spark igniter battery or backup batteries installed before 
reinstalling the front control panel.
Fig. # 10
PILOT 
FLAME 
INDICATOR
CONTROL
DOOR AND 
FRAME
GAS 
VALVE
BURNER 
SWITCH
CONDUIT
BATTERY SPARK 
IGNITER
MANUAL MILLIVOLT VALVE
6)  Reconnect "Pilot Flame" indicator wiring and reinstall 
control panel.
WINDOW
FRAME
HEARTH
EXTENSION
WINDOW
TRACK
SUB-
FLOOR
Fig. # 11