Step 1. Determine the desired location of the fireplace. Check to ensure that  wall studs
or roof rafters are not in the way when the venting system is attached. If this is
the case, you may want to adjust the location of the stove.
Step 2. Simpson  Dura-Vent  pipe  is  designed  with  special  twist-lock  connections.  To
connect the venting system to the stove flue outlet, a twist-lock adapter is built
into the stove at the factory.  Remember to include wall thickness in minimum
clearances when figuring the measurements for your installation needs.
Note: Twist-lock procedure: Four indentations, located on the female ends of pipes and
fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings by
orienting the four pipe indentations so they match and slide into the four entry slots on
the male ends, see Fig. 5  below.  Push the pipe sections completely together, then twist-
lock  one  section  clockwise  approximately  one-quarter  turn,  until  the  two  sections  are
fully locked. The female locking lugs will not be visible from the outside, on the pipe or
fittings. They may be located by examining the inside of the female ends.
NOTE:  Horizontal runs of vent must be supported every 3' (914mm). Wall straps are available
for this purpose.
HORIZONTAL INSTALLATION
NOTE:
Horizontal sections require a 1/4" (6mm) rise for every 12" (305mm) of horizontal
travel.
Exterior Vent Diameter = 6 5/8" (177mm); Inner Vent Diameter = 4" (101mm)
Horizontal sections require noncombustible support every 3' (914mm) , e.g. plumbing
tape.
FEMALE LOCKING LUGS
MALE LOCKING LUGS
VENTING