Remington QFP40 Manuel D’Utilisation

Page de 68
REMINGTON QFP40 Direct Vent FIREPLACE
Page 6
250-4721   JUNE 2001
1999  2000 2001  JAN   FEB  MAR  MAY  JUN  JUL   AUG  SEP    OCT  NOV   DEC
SAFETY 
LABEL
Location: Serial No. portion on lip below control panel.  Lower portion  behind access door on
baseplate to right of control panel.
1445 N. Highway
Colville, WA  99114
LP
NG
Input Rate on “HI” (BTU/Hr)
40,000
40,000
Input Rate on “LO” (BTU/Hr)
.
32,000
27,000
Maximum Output (BTU/Hr)
34,400
34,400
Main Burner Orifice Front (DMS)**
#56
#47
Main Burner Orifice Rear (DMS)**
#53
#42
Minimum Inlet Pressure (Inches W.C.)
11"
 4.5"
Maximum Inlet Pressure (Inches W.C.)
14"
 7.0"
Manifold Pressure on “HI” (Inches W.C.)
 10"
 3.5"
**Equipped for installation in Canada for altitudes of  0 - 4500' (1370M); and in USA for alti-
tudes of  0 - 2000' (610M).  In USA for altitudes above 2000' the vent configuration, orifice, or
combination of both may need to be changed.  See Owner’s Manual for information on making
these changes.
061-S-14-5
 APPROVED FOR CANADA AND USA TO:
ANSI Z21.88-1998/CSA 2.33-M1998 Vented Gas Fireplace Heaters and applicable sections of  UL307b
Gas Burning Heating Appliances for Mobile Homes and recreational vehicles, CAN/CGA 2.17-M91
“Gas-Fired Appliances for use at High Altitudes”.
  SERIAL    NO.
 
 FAN TYPE VENTED CIRCULATOR          Thermal Efficiency*  84% NG (blower on)
           Blower Electrical Rating:
                   86% LP (blower on)
   115V., 1.5 Amps,  60 Hz, 150 watts
                                                                                * With Maximum horizontal length.
                 MODEL:  REMINGTON
MODEL:  REMINGTON
  SERIAL    NO.
RATINGS PLATE