Hearth & Home Technologies Tucson (8700) Manuel D’Utilisation

Page de 44
HearthStone Quality Home Heating Products Inc
                                                                   Tucson 
Model #8700
 
 
9
 
SPECIFICATIONS: 
 
L
ISTED
D
IRECT
-V
ENT 
G
AS 
H
EATER
 
Listed: Gas-Fired Direct-Vent Fireplace Heater 
Model: Tucson Direct-Vent Gas Fireplace Heater 
Testing Agency: Intertek Testing Services NA Inc. (ITS) 
Tested to: ANSI Z21.88-1998, CSA 2.33-M98, CAN/CGA2.17 
Certified for Canada  
Approved for  
Mobile Home Installation (see page 7) 
 
                
 
 
Figure 1: Tucson Dimensions 
  
  
NG 
LP 
Input rating (Btu/hr) 0-1370 m 
 
26,000  26,000 
Maximum output (Btu/hr) 0-1370 m 
 
19,000  19,700 
Minimum input rating (Btu/hr)  
 
14,500  14,500 
Orifice size DMS 0-1370 m 
 
40 
53 
Man. pressure- HI setting (in.w.c./kPa) 
 
3.5/0.87 10.0/2.48 
Man. pressure- LO setting (in.w.c./kPa)   
1.2/0.30  3.3/0.80 
Inlet pressure-Lo (in.w.c./kPa) 
 
5.0/1.24 11.0/2.88