Hearth & Home Technologies TIARAI-BR-B Manuel D’Utilisation
Page 8
August 1, 2008
Heat & Glo · Tiara I B & Tiara II B · 7010-149M
Figure 3.1
A
G
A
A
B
F
E
A
"A" measurement is from
appliance top, not side
G
H
D
C
C
90˚ off top up and out ceiling
Model
A
B
C
D
E
F
G
H
Top of
pipe
Side of
pipe
Inside
Outside
corner
wall vent
Tiara II B
Inches
5-1/4
1/4
3/8
54
36
40
31-3/4
1-1/2
1
9
Millimeters
133
6
9.5
1372
914
1016
806
38
25
229
C. Clearances to Combustibles - Tiara II-B
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
For both the Tiara I-B and Tiara II-B, it is permissible to place
the appliance on carpet.
the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
appliance causing discoloration or odor.
Fire Risk.
Odor Risk.
Tipping Risk
• Install appliance on a stable, level platform/
Odor Risk.
Tipping Risk
• Install appliance on a stable, level platform/
fl oor strong enough to support appliance
without tipping.
without tipping.
• USE
wood
fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.
directly over the sub-fl ooring material.
WARNING