Page de 40
2.  Start  the  pilot  by  pressing  the  gas  control  knob  and  turning  it  to  PILOT.  
While  holding  the  gas  control  knob  in,  press  the  piezo  ignitor  several 
times until the pilot light starts. Hold the gas control knob in for thirty (30) 
seconds. Check that the pilot has fully engulfed the thermocouple assembly 
(see Figure 3).
3. Start the main burner by turning the gas control knob to ON and then turn 
the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
����������
������������
Figure 3.  Pilot flame.
R
EMOTE
 
CONTROLS
 (O
PTIONAL
):
This fireplace can use an optional remote control or an optional cordless wall thermostat.  If either of 
these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the 
control panel) in the remote/thermostat position.  Consult the instructions included with the remote/wall 
thermostat for operation guidelines.
B
LOWER
 S
PEED
 (O
PTIONAL
):
The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The 
speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob 
COUNTER CLOCKWISE until it “clicks” off. 
It is advisable not to operate the blower below 
1
/
3
 speed as it puts a strain on the windings of the blower 
and running the blower at lower speeds could also cause premature fan failure.
N
ORMAL
 S
OUNDS
 D
URING
 O
PERATION
:
Table 1: Normal Sounds
Component
Sound & Reason
Ascot
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The 
blower is pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
7
Operating Instructions
For Your Safety, Read Safety Precautions And 
Lighting Instructions Before Operating
P
ILOT
 L
IGHT
:
1. Turn off the gas to the fireplace.  If not recently done, remove the glass and let the unit air out 
for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints 
with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING.