State Industries SUF 100 250NE Manuel D’Utilisation

Page de 4
Multiple venting
options.
Ultra Force puts an end to most venting
difficulties. That’s because all models may
be installed using standard one-pipe venting
or by using two-pipe direct venting to
eliminate potential negative air pressure
issues. For ease and convenience, all vents
can also be run vertically or through the
sidewall. Models with BTU inputs of
120K-240K have venting distances of up 
to 50 eq. feet using standard 3˝ PVC, ABS
or CPVC pipe or up to 120 eq. feet using 
4˝ PVC, ABS or CPVC pipe. Models with
BTU inputs of 300K-400K have venting
distances of up to 70 eq. feet using 4˝ PVC,
ABS or CPVC pipe.
The new and improved Ultra Force
conveniently fits in the smallest possible
space to make it a practical choice for 
even more installations. All serviceable
components are accessible from the front
and top to make placement easy in a 
corner or flush against a wall. Plumbing
and venting connections are conveniently
located and provide greater flexibility. 
ULTRA FORCE
FITS ALMOST ANYWHERE.
For more information on Ultra Force SUF, contact:
State Water Heaters
500 Tennessee Waltz Parkway, 
Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com
Model 
Gallon
BTU/
First Hour
Recovery In GPH 
Height
Diameter
Depth 
Capacity Hr. 
Input
Delivery
@ 100˚ Rise
(Inches)
(Inches)
(Inches) 
Natural
LP
Natural
LP
Natural
LP
SUF 120 
60
120,000
120,000
180
180
138
138
55
1
/
2
27
3
/
4
30
SUF 150 
100
150,000
150,000
243
243
173
173
75
1
/
2
27
3
/
4
30
SUF 199 
100
199,000
199,000
300
300
230
230
75 
1
/
2
27
3
/
4
30
SUF 240 
100
240,000
240,000
346
346
288
288
75 
1
/
2
27
3
/
4
30
SUF 300 
130
300,000
300,000
440
440
349
349
75 
1
/
2
33
1
/
8
39
1
/
8
SUF 400 
130
399,900
399,900
557
557
466
466
75 
1
/
2
33
1
/
8
39
1
/
8
SCGBR00207
SUF 100 199NE
SUF 60 120NE
SUF 130 300NEA
SUF 100 150NE
SUF 100 250NE
SUF 130 400NEA
March 2008R
192669_SCGBR00207.indd   4
3/14/08   11:17:06 AM