Empire Comfort Systems 3)(N Manuel D’Utilisation

Page de 60
23552-4-0408
Page 47
DIRECT IGNITION PROPANE/LP GAS CONVERSION
Model
AIR SHUTTER 
SETTINGS
BURNER ORIFICE
Opening "A"
Propane/LP Orifice
DVD32 1/4" (6.4 mm)
#56
DVD36 1/4" (6.4 mm)
#55
DVD42 5/16" (7.9 mm)
1.45 mm
DVD48 5/16" (7.9 mm)
#52
“A”
REGULATOR FITTING
NOTE: STAMPED WITH
GAS TYPE SET FOR USE
Maxitrol Valve Conversion
Figure 62
Figure 63