The correct flame will be blue and will extend beyond the thermo-
couple.  The flame will surround the thermocouple just below the 
tip.  A slight yellow flame may occur where the pilot flame and 
main burner flame meet.
Figure 11
Oxygen Depletion Sensor Pilot (Figure 12)
When the pilot has a large yellow tip flame, clean the Oxygen 
Depletion Sensor as follows:
1.  Remove  pilot  from  main  burner  assembly,  see  "Appliance 
Maintenance", Page 13. 
2.  Apply air pressure through the holes in the pilot indicated by 
the arrows in Figure 12.  This will blow out foreign materials 
such as dust, lint and spider webs.  
Figure 12
Warning:  
Never use needles, wires, or similar cylindrical objects to clean 
the pilot to avoid damaging the calibrated ruby that controls 
the gas flow.
To ignite main burner, rotate gas control knob counterclockwise 
toward HI setting.  To shut down main burner, rotate gas control 
knob clockwise toward LO setting.
BF-10
The  gas  control  has  an  input  of  10,000    Btu/HR  (2.9  KW/H). 
The hydraulic thermostat bulb is located at the casing assembly 
bottom. 
BF-20
The gas control modulates from a minimum input of 8,500  Btu/HR 
(2.5 KW/H) (LO setting) to a maximum input of 20,000 Btu/HR 
(5.9 KW/H) for LP gas (HI setting) or 18,000 Btu/HR (5.3 KW/H) 
for Natural Gas (HI setting). The hydraulic thermostat bulb which 
is located at the casing assembly bottom adjusts the main burner 
flame between minimum input and maximum input.
BF-30
The gas control modulates from a minimum input of 8,500  Btu/HR 
(2.5 KW/H) (LO setting) to a maximum input of 30,000 Btu/HR 
(8.8 KW/H) (HI setting). The hydraulic thermostat bulb which is 
located at the casing assembly bottom adjusts the main burner flame 
between minimum input and maximum input.
Note:  When the hydraulic thermostat bulb is "satisfied" the main 
burner  flame  will  shut  "OFF"  with  the  pilot  flame  remaining 
"ON".
The LO and HI setting has temperature range of approximately 55°F 
(12.78°C) to 90°F (32.22°C) , respectively.  This is the temperature at 
the hydraulic thermostat bulb not the room temperature.  The owner 
is advised to determine the particular heat setting that is desired for 
comfort, as heating requirements are different for every owner.
Attention:  If the owner does not want the main burner to ignite 
and turns the gas control knob to the Lo setting, the main burner 
will still ignite if the temperature at the hydraulic thermostat bulb 
drops to 55°F (12.78°C). 
If  no  heat  is  desired,  turn  the  gas  control  knob  to  the  PILOT 
position.
PILOT FLAME CHARACTERISTICS
THERMOSTAT OPERATION