Empire Comfort Systems BF-20-2 Manuel D’Utilisation

Page de 20
16943-5-0806
Page 3
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
•  An  unvented  room  heater  having  an  input  rating  of 
more than 6,000 Btu per hour shall not be installed in a 
bathroom.
•  An unvented room heater having an input rating of more 
than 10,000 Btu per hour shall not be installed in a bedroom 
or bathroom.
•  Due to high temperatures,  the appliance should be located 
out of traffic and away from furniture and draperies.
•  Children and adults should be alerted to the hazard of  
high surface temperature  and should stay away to avoid 
burns or clothing ignition.
•  Young children should be carefully supervised when they 
are in the same room with the appliance.
•  Do not place clothing or other flammable material on or 
near the appliance.
•  Due to high surface temperatures, keep children, clothing 
and furniture away.
•  WARNING: Do not use a blower insert, heat exchanger 
insert  or  other  accessory  not  approved  for  use  with 
heater.
•  Installation and repair should be done by a QUALIFIED 
SERVICE PERSON.  The  appliance should be inspected 
before use and at least annually by a professional service 
person.   More frequent cleaning may be required due to 
excessive lint from carpeting, bedding materials, etc.  It 
is  imperative  that  control  compartments,  burners  and 
circulating  air  passageways  of  the  appliance  be  kept 
clean.
•  DO NOT use this room heater if any part has been under 
water.    Immediately    call  a  qualified  service  technician 
to inspect the room heater and to replace any part of the 
control system and any gas control which has been under 
water.
•  Keep  appliance  area  clear  and  free  from  combustible 
materials,    gasoline  and  other  flammable  vapors  and 
liquids.
•  WARNING: ANY CHANGE TO THIS HEATER OR ITS 
CONTROLS CAN BE DANGEROUS.  
  Any  safety  screen  or  guard  removed  for  servicing  an 
appliance must be replaced prior to operating the heater.
•  WARNING: Failure to keep the primary air opening(s) 
of the burner(s) clean may result in sooting and property 
damage.
WARNING
When  used  without  adequate  combustion  and  ventilation  air, 
heater may give off CARBON MONOXIDE, an odorless, poi-
sonous gas. 
Do not install heater until all necessary provisions are made 
for combustion and ventilation air.  Consult the written in-
structions provided with the heater for information concerning 
combustion and ventilation air.  In the absence of instructions, 
refer to the National Fuel Gas Code, ANSI Z223.1, Section 
5.3 or applicable local codes. 
This heater is equipped with a PILOT LIGHT SAFETY SYS-
TEM designed to turn off the heater if not enough fresh air is 
available.
DO  NOT  TAMPER  WITH  PILOT  LIGHT  SAFETY 
SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced.  Keep burner and 
control compartment clean. 
CARBON MONOXIDE POISONING MAY LEAD TO 
DEATH.
Early signs of carbon monoxide poisoning resemble the flu, with 
headache, dizziness and/or nausea.  If you have these signs, heater 
may not be working properly.  Get fresh air at once!  Have heater 
serviced.  
Some people — pregnant women, persons with heart or lung dis-
ease, anemia, those under the influence of alcohol , those at high 
altitudes — are more affected by carbon monoxide than others.
The pilot light safety system senses the depletion of oxygen at 
its location.  If this heater is installed in a structure having a high 
vertical dimension, the possibility exists that the oxygen supply 
at the higher levels will be less than that at the heater.  In this type 
of application, a fan to circulate the structure air will minimize 
this effect.  The use of this fan will also improve the comfort level 
in the structure.  When a fan is used to circulate air, it should be 
located so that the air flow is not directed at the burner.
IMPORTANT SAFETY INFORMATION