Figures 13 and 16  show a correct  pilot flame pattern. The correct flame 
will be blue and will extend beyond the thermocouple. The flame will 
surround the thermocouple just below the tip.  A slight yellow flame may 
occur where the pilot flame and main burner flame meet.  Figures 14 and 
17 show an incorrect pilot flame pattern.  The incorrect pilot flame is not 
touching the thermocouple. This will cause the thermocouple to cool.  
When the thermocouple cools, the heater will shut down.
VFCR-25 PILOT
Correct Pilot Flame Pattern
Figure 13
Incorrect Pilot Flame Pattern
Figure 14
If pilot flame pattern is incorrect, as shown in Figure 14
•  See Troubleshooting, page 19.
Cleaning and Maintenance/Pilot
Oxygen Depletion Sensor Pilot 
When the pilot has a large yellow tip flame, clean the Oxygen Depletion 
Sensor as follows:
1.  Clean the ODS pilot by loosening nut B from the pilot tubing. When 
this procedure is required, grasp nut A with an open end wrench.
2.  Blow air pressure through the holes indicated by the arrows. This 
will blow out foreign materials such as dust, lint and spider webs. 
Tighten nut B also by grasping nut A. 
Figure 15
VFCM-25  AND VFCT-25 PILOT
Correct Pilot Flame Pattern
Figure 16
Incorrect Pilot Flame Pattern
Figure 17
If pilot flame pattern is incorrect, as shown in Figure 17
•  See Troubleshooting, page 19.
PILOT FLAME CHARACTERISTICS