Empire Comfort Systems VFCT25-3 Manuel D’Utilisation

Page de 24
Page 5
16937-4-0806
INTRODUCTION
I
nstructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer must have owner fill out and mail warranty card 
supplied with unvented room heater.
3.  Installer should show owner how to start and operate unvented 
room heater.
Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation 
of an unvented room heater.
This appliance may be installed in an aftermarket* permanently 
located, manufactured (mobile) home, where not prohibited by 
state or local codes.
*Aftermarket:  Completion of sale, not for purpose of resale, from 
the manufacturer.
This appliance is only for use with the type of gas indicated on 
the rating plate.
WARNING: ANY CHANGE TO THIS HEATER OR ITS 
CONTROLS CAN BE DANGEROUS. 
Any safety screen or guard removed for servicing an appliance 
must be replaced prior to operating the heater.
General Information
This  unvented  heater  is  design  certified  in  accordance  with 
American National Standards Institute Z21.11.2 by the Canadian 
Standards Association as an Unvented Room Heater and should 
be installed according to these instructions.
Attention: During initial use of ceramic log you will detect an 
odor as the ceramic log is cured. Also, during the curing process 
the ceramic log will burn with a yellow flame.
Any  alteration  of  the  original  design,  installed  other  than  as 
shown in these instructions or use with a type of gas not shown 
on the rating plate is the responsibility of the person and company 
making the change.
Important
All  correspondence  should  refer  to  complete  Model  Number, 
Serial Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out, 
and smoke will occur. To prevent triggering of smoke alarms, 
ventilate the room in which the unit is installed.
Qualified Installing Agency
Installation  and  replacement  of  gas  piping,  gas  utilization 
equipment or accessories and repair and servicing of equipment 
shall be performed only by a qualified agency. The term "qualified 
agency"  means  any  individual,  firm,  corporation  or  company 
which either in person or through a representative is engaged in 
and is responsible for (a) the installation or replacement of gas 
piping or (b) the connection, installation, repair or servicing of 
equipment, who is experienced in such work, familiar with all 
precautions required and has complied with all the requirements 
of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a 
licensed plumber or gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural gas-fired supplemental 
room heaters shall provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
The installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54.*
*Available from the American National Standards Institute, Inc., 11 West 42nd 
St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be 
reduced at the rate of 4 percent for each 1,000 feet (305m) above 
sea level. Contact the manufacturer or your gas company before 
changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the 
Btu output of the unit. Contact the gas company for the heating 
value.  Contact  the  manufacturer  or  your  gas  company  before 
changing spud/orifice size.
WARNING: Failure to keep the primary air opening(s) of the 
burner(s) clean may result in sooting and property damage.
Model 
VFCR-25 
VFCM-25 
VFCT-25
Input  BTU/HR (KW/H) 
 
Max. (LP/NAT)  
25,000 ( 7.3) 
25,000 (7.3) 
25,000 ( 7.3)
 
Medium 
——  
20,000 (5.9) 
—— 
 
Min. (LP/NAT) 
17,500 (5.1) 
15,000 (4.4) 
17,500 (5.1)
Height     
26 3/4" (679mm) 
26 3/4" (679mm) 
26 3/4" (679mm)
Width  
26 1/4" (666mm) 
26 1/4" (666mm) 
26 1/4" (666mm)
Depth  
17 1/8" (434mm) 
17 1/8" (434mm) 
17 1/8" (434mm)
Gas Inlet  
3/8" (9.5mm) 
3/8" (9.5mm) 
3/8" (9.5mm)
Stove Casting (Requires VFCR-25, VFCT-25, VFCM-25
VFCI-FB 
Vent-Free Cast Iron Stove Painted Black
Accessories for VFCR-25 Only 
TMV 
Wall Thermostat, Millivolt -Reed Switch
FRBC 
Battery Operated Remote Control 
FRBTC 
Battery Operated Remote Control with Thermostat
FREC 
Electric Remote Control
FWS-1 
Wall Switch
SPECIFICATIONS
BRUCE SPECIAL COPY