Empire Comfort Systems DV33IN33L Manuel D’Utilisation

Page de 28
23015-3-0707
Page 22
INSERT MAINTENANCE AND SERVICE
Although the frequency of servicing and maintenance will depend 
on use and the type of installation, you should have a qualified 
service technician perform an appliance checkup at the beginning 
of  each  heating  season.  Specific  guidelines  regarding  each 
appliance maintenance task are listed below.
IMPORTANT: TURN OFF THE GAS BEFORE SERVICING 
YOUR APPLIANCE.
Cleaning Burner and Controls
Frequency: Once annually.
By: Qualified service technician.
Task: Brush or vacuum the control compartment, fireplace logs 
and burner areas surrounding the logs.
Checking Flame Patterns, Flame Height
Frequency: Periodically.
By: Qualified service technician/Home owner.
Task: Make a visual check of your fireplace’s flame patterns.
Make  sure  the  flames  are  steady  -  not  lifting  or  floating.  The 
thermopile/thermocouple (standing pilot) tips should be covered 
with flame. See Figure 21.
Checking Vent System
Frequency:  Before  initial  use  and  at  least  annually  thereafter, 
more frequently if possible.
By: Qualified service technician/Home owner.
Task: Inspect the external vent cap on a regular basis to ensure 
that no debris is interfering with the flow of air. Inspect entire vent 
system for proper function.
Cleaning Logs
Use a soft brush attachment on a vacuum cleaner to gently remove 
dust or soot deposits from logs and burner.
Cleaning Glass Door
Frequency: After the first 3 to 4 hours of use. As necessary after 
initial cleaning.
By: Home owner.
Task: Remove and clean glass after the first 3 to 4 hours of use. 
After the initial cleaning, clean as necessary. Film deposits on the 
inside of the glass door should be cleaned off using a household 
glass cleaner.
NOTE: DO NOT handle or attempt to clean the door when it 
is hot and DO NOT use abrasive cleaners.
Glass Door Replacement
Do not operate the fireplace insert if the high-temperature ceramic 
glass is cracked or broken.
Do  not  attempt  to  replace  the  ceramic  glass  panel. A  complete 
replacement glass door assembly should be ordered as listed in 
the Parts List on page 25, if needed.
Do  not  use  substitute  materials  for  replacement  of  glass  door 
components.
Do not abuse the glass door by striking the glass.
Do  not  abuse  the  glass  door  by  slamming  or  forcing  the  door 
shut.
When installing the glass door assembly, place the top door flange 
over  the  firebox  top,  center  left  to  right,  then  gently  swing  the 
door  bottom  inward  and  secure  with  the  two  (2)  spring  loaded 
door latches.