INSTALLATION
WALL SWITCH INSTALLATION
Since the VDVF36TPNEA/TSTEA series uses a 24 
VAC current supplied from a transformer mounted 
on the ignition module and is prewired for easy 
connection to a wall switch (see Figure 34). The 
(V)DVF36TPNA/TSTA models use a self gener-
ated millivolt current that allows you to activate 
the gas control valve directly without the use of 
normal household electricity (see Figure 35). Both 
versions are supplied with a wall switch kit for ready 
connection and mounting.
  WARNING:  Do  not  wire  re-
mote wall switch to main power 
supply  (Standard  120v  house-
hold current).
1.  To remove the louvers, simultaneously pull 
both top end spring latches towards the center 
of the appliance until they are disengaged 
from locating holes. Repeat for bottom spring 
latches and pull louvers outward. Reverse the 
procedure to install louvers back onto the ap-
pliance (see Figure 36).
2.  Connect the 18 ga. wires from wall switch to 
the gas control valve terminals marked TH 
and TPTH or to the ignition module using the 
pigtails and wire nut connectors supplied with 
the appliance.
 CAUTION: Due to high tem-
peratures, make sure wires are 
not touching upper firebox.
Figure 36 - Removing Louver
Glass
Locating 
Holes
Spring 
Latch
Figure 35 - Wall Switch Wiring Diagram, 
Millivolt Units
Note:
 If any of the original wire supplied must be 
replaced, use type 18 AWG-105 degree C (25 feet 
length maximum) or equivalent.
OFF
  P
IL
O
 ON 
LO
        HI 
PI
LOT 
E
A
16AI
7
TPTH        
TP
         
TH
Wall Switch 
(Supplied)
Route Millivolt Wires 
(Supplied) Through Gas 
Line Conduit Sleeve
To 
Thermopile
V1
SW
SI
TS
IND
V2
L1
D
N
G
P.
Figure 34 - Wall Switch Wiring Diagram, 
Electronic Units
Route 4V (Supplied)
Through Electrical 
Conduit Bushing
Electrode
Transformer
Plug 10V AC
To Receptacle
18 AWG
Red Wire
To Gas V
alve
Wall Switch
(Supplied)
Make Connections 
with Wirenuts 
(Supplied)
Ignition 
Control 
Module
(Back 
View)
(Back 
View)
ELECTRICAL HOOKUP FOR 
OPTIONAL BLOWER ACCESSORY
Before blower accessory can be operated, the ap-
pliance outlet box must be properly connected to 
a standard 120 VAC power source. This must be 
done when the appliance is originally installed. 
Refer to Wiring Diagrams on page 33.
An outlet box with two receptacles has been sup-
plied for your convenience and is located on the 
lower right side of the appliance (see Figure 37, 
page 22). The variable speed controller is mounted 
on a magnetic base and may be positioned any-
where within an accessible distance behind the 
louvered opening (see Figure 36).
Recommended 
Blower Speed 
Control Location
OFF
  P
IL
O
 ON 
LO
        HI 
PI
LOT 
E
A
16AI
7
TPTH        
TP
         
TH
V1
SW
SI
TS
IND
V2
L1
D
N
G
P.