VENTING INSTALLATION 
INSTRUCTIONS
Continued
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been CSA tested and approved 
for elevations from 0-2000 feet (USA) and elevations from 0-4500 
feet (Canada).
When installing this fireplace at an elevation above 2000 feet (in 
the USA), you may need to decrease the input rating by changing 
the existing burner orifice to a smaller size. Reduce input 4% for 
each 1000 feet above sea level. Check with your local gas company 
for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in 
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice 
for your location.
For assistance with any high altitude installation contact DESA 
Customer Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND 
COMPONENtS
DESA Pipe & Vent Kits
Number  Description
P58-6 
6" Section Double Wall Pipe - Galvanized
P58-12 
12" Section Double Wall Pipe - Galvanized
P58-24 
24" Section Double Wall Pipe - Galvanized
P58-36 
36" Section Double Wall Pipe - Galvanized
P58-48 
48" Section Double Wall Pipe - Galvanized
PA58-712  Adjustable 7"-12" Section Coaxial Pipe - Galvanized
FPA58-6  6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe 
Section)
DPA58-6  6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe 
Section
E58-45 
45° Elbow, Galvanized
E58-90 
90° Elbow, Galvanized
FSE58-45  45° Starter Elbow, Galvanized (Duravent Collar to FMI 
Pipe)
DSE58-45 45° Starter Elbow, Galvanized (FMI Collar to Duravent 
Pipe)
VKG-58 
Ground Floor Vent Kit - Galvanized
VKB-58 
Basement Vent Kit - Galvanized
VKS-58 
Snorkel Kit - Galvanized
VKR-58 
Roof Vent Kit - Galvanized
VKC-58 
Corner Vent Kit - Galvanized
HTK 
Horizontal Round Termination Kit
HT-58 
Horizontal Round Termination Kit, Galvanized
HTKS-58  Horizontal Square Termination Kit
HTS-58 
Horizontal Square Termination Kit, Galvanized
VT-58 
Vertical Round Termination, Galvanized
ST-58-14  14" Snorkel Termination, Galvanized
Number  Description
ST-58-36  36" Snorkel Termination, Galvanized
SC-58 
Storm Collar - Galvanized
WF-58 
Wall Firestop - Galvanized
RF-58-6  Roof Flashing - 0 to 6/12 Pitch - Galvanized
RF-58-12  Roof Flashing - 6/12 to 12/12 Pitch - Galvanized
VR-58 
Vertical Restrictor - Galvanized
S-58 
Vinyl Siding Standoff - Galvanized
WS-58 
Wall Strap
CS-58 
Cathedral Ceiling Support
FP-58 
Firestop Plate
SF-58 
Stucco Flashing - For use with HTS-5
FIREPLACE INSTALLATION
CHECK GAS tYPE
Use proper gas type for the fireplace unit you are installing. If you 
have  conflicting  gas  types,  do  not  install  fireplace.  See  retailer 
where you purchased the fireplace for proper fireplace according 
to your gas type.
INSTALLING OPTIONAL bLOWER 
ACCESSORIES
NOtICE: If installing blower in an existing fireplace with 
gas connections, shut off gas supply and disconnect 
heater  from  gas  supply.  Contact  a  qualified  service 
person to do this.
 WARNING: If there is a duplex electrical outlet in-
stalled in the right side of the bottom of the fireplace 
base area, be sure that the electrical power to the outlet 
is turned off before proceeding with blower installation. 
Failure to do this may result in serious injury.
Model bK Installation
Follow all instructions provided in the blower accessory kit.
1.  Attach the power cord to the blower motor by firmly pushing 
the two female terminals at the end of the power cord onto the 
two spade terminals on the blower motor (see Figure 25).
Figure 25 - Blower Model BK
Magnetic 
Strips
Exhaust 
Port
Screw
Green 
Ground Wire
Spade 
Terminals
Side View
Lower Firebox 
Cavity
Blower 
Location