Desa CD42M-A2 Manuel D’Utilisation

Page de 24
www.desatech.com
111916-01F
15
D.  Do not use this appliance if any part has been 
under water. Immediately call a qualified 
service technician to inspect the appliance and 
to replace any part of the control system and 
any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1.  STOP! Read the safety information above 
before proceeding.
2.  Set the “HI-LO” knob to the lowest setting.
3.  Turn off all electrical power to the appliance.
4.  Open control access panel.
5.  Push in gas control knob slightly and turn 
clockwise 
 to “OFF”.
6.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information above. If you donʼt smell 
gas, go to the next step.
7.  The pilot is located by the main burner.
8.  Turn knob on gas control counterclockwise 
 to “PILOT”.
9.  Push in the control knob all the way and hold 
in. Immediately light the pilot by pressing the 
red ignitor button until a flame appears. Con-
tinue to hold the control knob in for about one 
(1) minute after the pilot is lit. Release knob 
and it will pop back up. Pilot should remain 
lit. If it goes out, repeat steps 5 through 9.
• If knob does not pop out when released, stop 
and call service technician or gas supplier.
• If the pilot will not stay lit after several tries, 
turn gas control knob to “OFF” and call 
your service technician or gas supplier.
10.  Turn gas control knob counterclockwise 
 to “ON”. Knob can be turned to “ON” 
only if the control knob is popped out.
11.  Set “HI-LO” knob to desired setting.
12.  Turn on all electric power to the appliance.
Note:
 It is recommended that you maintain the 
gas control knob in the full OFF position during 
lengthy periods of seasonal non-usage.
OPERATING FIREPLACE
Continued
Figure 32 - Control Knob in Pilot Position
Figure 33 - Pilot
Thermocouple
Pilot Burner
Piezo 
Ignitor
Thermopile
Position 
Indicator
Gas Control 
Knob
HI/LO Knob
TO TURN OFF GAS
TO APPLIANCE
1.  Turn off the wall switch.
2.  Turn off all electric power to the appliance 
if service is to be performed.
3.  Remove control access panel.
4.  Push in gas control knob slightly and turn 
clockwise 
 to “OFF”. Do not force.
5.  Replace control access panel.
CONVERTING FIREPLACE 
FROM NATURAL GAS TO 
PROPANE/LP GAS
The conversion kit is packaged with the unit. 
Please  check  the  contents  before  beginning 
this conversion.
 WARNING: Before proceed-
ing, make sure the gas control 
valve is in the OFF position and 
all electrical power to the appli-
ance is turned off.
CONVERTING PILOT
1.  Wait five (5) minutes to clear out any gas. Smell 
for any gas odor, especially near the floor. If any 
gas odor is present, STOP! See For Your Safety 
Read Before Lighting on page 14.
2.  Locate  the  latch  on  the  louver  assembly. 
Remove top and bottom louvers by pulling 
the spring latches toward the center of the 
fireplace simultaneously until they are disen-
gaged from the locating holes.
3.  Undo latches located on top and bottom of fire-
box and swing door to the fully open position.
4.  Carefully remove log set and ember material from 
burner and place them aside in a safe place.
5.  Replace main burner orifice with burner orifice 
included in conversion kit (Model CD42M-A 
series contains two burner orifices).