Lava Rock and Ember Material
1.  For all models, place lava rock along sides and 
front of firebox bottom in areas that are visible. It 
is not necessary to use all lava rock provided. 
NOTICE:  Do  not  put  lava  rock 
on  or  under  burner.  Placing 
lava rock on burner could cause 
performance problems.
2.  Pull ember material apart into pieces no larger 
than a dime. Place loosely and directly onto 
exposed section of front burner and along space 
between burner and grate prongs. These will cre-
ate glowing ember appearance as flame touches 
ember material. Do not block air slots by using 
too much ember material in one area. It is not 
necessary to use all ember material provided. 
3.  When lava rock and ember material are in 
place, close and latch glass door and secure 
louvers in place.
  WARNING:  The  glass  door 
must be securely in place before 
operating fireplace. Do not oper-
ate fireplace if glass is missing 
or broken.
DECORATIVE FACING
Any noncombustible material may be used as fac-
ing (glass, tile, brick, etc.) as long as the proper 
clearances are observed (see Clearances to Com-
bustibles, page 4). Louvered openings must not 
be obstructed and upper and lower panels must 
remain accessible for service. Use only heat-re-
sistant, noncombustible mortar or adhesive when 
securing decorative facing materials.
FACE EXTENSION FOR MODEL 
CD32M ONLY
Model CD32M comes equipped with a front face 
extension. The front face extension would add 
1
/
2
" to the width and 3/4" to the height of the 
fireplace face.
To install face extension:
1.  Remove existing screws from front face as-
sembly as shown in Figure 29.
2.  Align holes on top face extension with holes on 
top side of front face assembly and secure with 
screws previously removed (see Figure 29). 
INSTALLATION 
Continued
3.  Align holes on right face extension with holes 
on right side of front face assembly and secure 
with screws previously removed (see Figure 
29). Do the same for left side.
4.  Secure top face extension with left and right 
face extensions with two sheet metal screws 
(see Figure 29).
Figure 29 - Front Face Extension, Model 
CD32M Only
BURNER FLAME 
ADJUSTMENT
The burner flame adjustment (shutter opening) has 
been factory preset (for natural gas) to the proper 
air-to-gas ratio. This ratio results in an even, clean 
burning flame across the burner (see Figure 30).
Figure 30 - Burner Flame Patterns
CORRECT
INCORRECT
CLOSE 
SHUTTER
INCORRECT
OPEN 
SHUTTER
Short, Sharp, Blowing Flame
Long, Blue Flame with Yellow Tips
Long, Uneven, Yellow Flame
Side Face 
Extensions
Top Face 
Extension