Desa CD36M-A2 Manuel D’Utilisation

Page de 24
www.desatech.com
111916-01F
3
INTRODUCTION
 WARNING: This product con-
tains and/or generates chemicals 
known to the State of California 
to cause cancer or birth defects 
or other reproductive harm.
Models  CD32M  series,  CD36M-A  series  and 
CD42M-A  series  are  heat  circulating  grav-
ity direct-vent fireplaces with sealed combustion 
chamber. These fireplaces use millivolt gas control 
valve and millivolt ignition system.
These fireplaces are convertible with the standard 
setup as natural gas. Conversion may be performed 
by the O.E.M. mobile home builder or by a quali-
fied service person on-site. If you are uncertain as 
to what gas your unit is equipped for, please check 
the rating plate located inside of the appliance 
opening or consult your mobile home supplier or 
your local distributor of DESA/Vexar products.
NOTICE:  Check  local  building 
codes for area requirements be-
fore installing this appliance.
BEFORE YOU BEGIN
Before beginning the installation of your appli-
ance, read these instructions through completely.
This DESA/Vexar fireplace and its components are 
safe when installed according to this installation 
manual and operated as recommended. Unless 
you use DESA/Vexar components designed and 
tested for this fireplace system, 
YOU MAY CAUSE 
A SAFETY HAZARD!
The DESA/Vexar warranty will be voided by, and 
DESA/Vexar disclaims any responsibility for the 
following actions:
A) Modification  to  the  fireplace,  components, 
doors, blower, fans or vent system.
B) Use of any component part not manufactured or 
approved by DESA/Vexar in combination with 
a DESA/Vexar fireplace system.
Proper installation is the most important step in 
ensuring  safe  and  continuous  operation  of  the 
fireplace. Consult the local building codes as to the 
particular requirements concerned with the instal-
lation of all factory built fireplaces. This fireplace, 
when installed, must be electrically grounded in 
accordance with local codes or in the absence of 
local codes, with the National Electrical Code, 
ANSI/NFPA 70 or the Canadian Electrical Code, 
CSA C22.1.
The installation must conform with local codes or, 
in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1 or the Canadian Installa-
tion Code, CAN/CGA B149. This appliance com-
plies with ANSI Z21.88-1998 and CSA 2.33-M98 
as a VENTED GAS FIREPLACE HEATER. 
SELECTING LOCATION
To determine the safest and most efficient loca-
tion  for  your  fireplace,  consider  the  following 
guidelines:
1.  The location must allow for proper clearances 
(see Figure 1).
2.  Consider a location where the fireplace would 
not  be  affected  by  drafts,  air  conditioning 
ducts, windows or doors.
3.  A location that avoids the cutting of joists or roof 
rafters makes ventilation installation easier.
In selecting a location, the following precautions 
must be observed:
•  Do not connect this appliance to a chimney 
system used for solid fuel burning fireplace.
•  Due to high temperatures, do not locate this 
appliance in high traffic areas or near furniture 
and draperies.
•  Never obstruct the openings of the appliance 
or  flow  of  ventilation  air.  Keep  the  control 
compartments accessible.
Figure 1 - Common Fireplace Locations
FULL
PROJECTION
CORNER
INSTALLATION
FLUSH
INSTALLATION
Flush installation is recommended where living 
space is limited.
Projected installation may be ideal for a new 
addition to an existing finished wall.
Corner installation makes use of a space that may 
not normally be used and provides a wider and 
more efficient range for radiant heat transfer.