Delkin Devices EI - 25-1 Manuel D’Utilisation

Page de 44
EURO 25 -1                                                              7 
GENERAL INFORMATION 
This appliance is tested and certified to the following U.S. and Canadian gas appliance standards. 
- ANSI Z 21.88b-2003 / CSA 2.33b-2003, Vented Gas Fireplace Heater 
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. 
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of these 
appliances. 
APPLIANCE CERTIFICATION 
INSTALLATION CODES 
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local 
codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the 
US or Installation Code, CAN/CGA-B149, in Canada. Electrical connections and grounding must conform with 
local code, or current National Electrical code, ANSI/NFPA No. 54, in the U.S. and in Canada, the current 
Canadian Electrical Code, CSA C22.1. This appliance is certified for installation in a bedroom or a bedsitting room 
and conforms to CR89-001. 
HIGH ALTITUDE INSTALLATION  
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-rated 
and installed according to local codes, in the absence of local codes, with the current National Fuel Gas Code, 
ANSI Z223.1/ NFPA 54, in the U.S. or Installation Code, CAN/CGA-B149, in Canada. 
 
Natural Gas (NG) 
Propane (LP) 
Manifold Pressure 
1.7 - 3.5 in. w.c. (0.4 - 0.9 kPa) 
6.3 - 10.0 in. w.c. (1.6 - 2.5 kPa) 
Minimum Supply Pressure for 
Purpose of Input Adjustment  
4.5 in. w.c. (1.2 kPa) 
11.0 in. w.c. (2.8 kPa) 
Maximum Supply Pressure for 
Purpose of Input Adjustment  
14.0 in. w.c. (3.6 kPa) 
14.0 in. w.c. (3.6 kPa) 
Orifice Size 
Cap #45 DMS (2.08 mm dia.) 
Cap #55 DMS (1.32 mm dia.) 
Nominal Input Rating 
15,000 - 20,000 BTU/hr (4.4 - 5.8 kW)   16,000 -20,000 BTU/hr (4.6 - 5.8 kW) 
Altitude 
0 - 4,500 ft. (0 - 1372 m) 
0 - 4,500 ft. (0 - 1372 m) 
Primary Air Opening 
3/16 in. (5 mm) 
Fully Open 
SPECIFICATIONS