Hampton Direct U32 Manuel D’Utilisation

Page de 40
33
U32-5 FPI Direct Vent Gas Insert
MAINTENANCE
VALVE REPLACEMENT
1)  Shut off the gas supply.
2)  Remove the louvers (and  bay door if it is 
on).
3)  Open the fl ush door and remove the door.
4)  Remove the logs and brick panels.
5)  Remove the grate by loosening the two 
screws and sliding the grate out.
12)  Remove the valve by  removing the 4 screws 
in the base of the valve tray.
Grate screws
6)  Remove the burner  assembly by  removing 
the 2 screws and lifting it out.
7)  Remove the 2 screws holding the Air Intake 
Hood to the rear fi rebox wall and lift out.
8)  Disconnect the inlet gas line.
9)  Disconnect the TP wire, the TH wire, and 
the TH/TP wire from the valve.
10) Remove the 11 Phillips head screws securing 
the valve tray in place. and then lift the entire 
assembly out.
5)  Reconnect the pilot tube nut with a 7/16" 
wrench.
6)  Re-attach the valve mounting bracket to the 
valve tray. 
Note: when installing the burner assembly 
be sure to slide the aeration adjustment wire 
through the hole in the base of the burner 
tray.
12) Install the grate.
13) Hook up the gas line and check for gas 
leaks with a soap and water solution or a 
gas leak detector. (Do not use open fl ame 
for leak testing.)
13) Fire up the unit temporarily and check the 
manifold pressure.
14)  Reinstall the vermiculite, embers, rockwool, 
logs and brick panels as needed.
15) Close the door and replace the louvers.
16) Fire up the unit again and check for proper 
fl ame appearance and glow on logs.
13) Undo the pilot tube from the valve with a
 7/16" 
wrench.
14) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) wrench.
15) Undo the "gas out" fl are nut with a 13/16" 
wrench.
16)  Undo the "gas out" fl are fi tting with an 11/16" 
wrench.
17) Remove the valve mounting brackets.
11) Push the valve assembly to the left and lift 
the entrire assembly out. 
Hint: If you are using black pipe, ensure that 
there is a union by the valve, otherwise removal 
will be almost impossible.
INSTALLING VALVE
1)  Re-attach the valve mounting brackets to  
the valve.
2)  Reconnect the "gas out" fl are fi tting with an 
11/16" wrench.
3)  Reconnect the "gas out" fl are nut with a .
 13/16" 
wrench.
4)  Reconnect the quick drop out thermocouple 
nut with a 9mm wrench.
7)  Scrape off the old gasket from the fl oor of 
the fi rebox and from the valve tray.
8)  Install a new gasket and reinstall the 
valve assembly.
Note: Failure to install a new gasket may 
severely affect the appliance performance.
9)  Reinstall the 11 hold down screws.
10) Hook up the TP,  TH, and TP/TH wires to 
the appropriate connections on the valve.
11) Reinstall the burner assembly.