Desa CBP20TK Manuel D’Utilisation

Page de 32
www.desatech.com
107882-01K
15
O
FF
PIL
OT
5.  Turn control knob counterclockwise 
 
to  the  PILOT  position.  Press  in  control 
knob for five (5) seconds (see Figure 19). 
 
Note:
 You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be 
pressed in for 30 seconds or more. This will 
allow air to bleed from the gas system.
• If control knob does not pop up when 
released, contact a qualified service person 
or gas supplier for repairs.
6.  With control knob pressed in, push down 
and release ignitor button (see Figure 19). 
This will light pilot. The pilot is attached to 
the front of burner. The pilot can be seen 
through the glass panel. If needed, keep 
pressing ignitor button until pilot lights.
 
Note:
 If pilot does not stay lit, refer to 
Troubleshooting, page 19. Also contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure, page 16.
7.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
• If control knob does not pop up when 
released, contact a qualified service person 
or gas supplier for repairs.
 
Note:
  If  pilot  goes  out,  repeat  steps  3 
through 7. This heater has a safety interlock 
system. Wait one (1) minute before lighting 
pilot again.
8.  Turn control knob counterclockwise 
 
to desired heating level. The main burner 
should light. Set control knob to any heat 
level between 1 and 5.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
OPERATING HEATER
Continued
Figure 19 - Control Knob In The OFF 
Position (Piezo Ignitor Shown)
Ignitor Button
Control Knob
Figure 20 - Pilot (actual pilot may vary)
Ignitor Electrode
Pilot Burner
Thermocouple
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Turn off all electric power to the appliance 
if service is to be performed. 
Shutting Off Burner Only (pilot stays lit)
Turn  control  knob  clockwise 
  to  the 
PILOT position.
THERMOSTAT  
CONTROL OPERATION
The thermostatic control used on these models 
differs from standard thermostats. Standard 
thermostats simply turn on and off the burner. 
The thermostat used on this heater senses the 
room temperature. The thermostat adjusts the 
amount of gas flow to the burner. This increases 
or decreases the burner flame height. At times 
the room may exceed the set temperature. If so, 
the burner will shut off. The burner will cycle 
back on when room temperature drops below 
the set temperature. The control knob can be set 
to any heat level between 1 and 5. Selecting the 
5 setting will cause the burner to remain fully on 
without modulating down in most cases.
Note:
 The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This may not always agree with room tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.). Frequent use of your heater will 
let you determine your own comfort levels.