Test Pressures Equal To or Less Than 
1/2 PSIG (3.5 kPa)
1.  Close equipment shutoff valve (see Fig-
ure 16).
2.  Pressurize supply piping system by either 
opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas or using compressed air.
3.  Check all joints from gas meter for natural 
gas (see Figure 17) or propane/LP supply 
tank  for  propane/LP  gas,  to  equipment 
shutoff  valve  (see  Figure  18). Apply  a 
noncorrosive  leak  detection  fluid  to  all 
joints. Bubbles forming show a leak.
4.  Correct all leaks at once.
PRESSURE TESTING HEATER GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Fig-
ure 16).
2.  For natural gas open main gas valve lo-
cated on or near gas meter. For propane/
LP  gas  open  propane/LP  supply  tank 
valve.
3.  Make sure control knob of heater is in the 
OFF position.
4.  Check  all  joints  from  equipment  shutoff 
valve to thermostat gas valve (see Figure 
17 or 18). Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles forming 
show a leak.
5.  Correct all leaks at once.
6.  Light  heater  (see  Operation,  page  15). 
Check all other internal joints for leaks.
7.  Turn off heater (see To Turn Off Gas to 
Appliance, page 16).
8.  Replace front panel.
Figure 18 - Checking Gas Joints for 
Propane/LP Gas (actual heater may vary 
from illustration)
Equipment Shutoff Valve
Propane/LP 
Supply Tank
Thermostat Gas Valve
Figure 17 - Checking Gas Joints for 
Natural Gas (actual heater may vary from 
illustration)
Equipment Shutoff Valve
Gas 
Meter
Thermostat Gas Valve
INsTallaTIoN
Continued
Figure 16 - Equipment Shutoff Valve
Open
Closed
Equipment 
Shutoff Valve