Haier HSU-09HRA103/R2 Manuel D’Utilisation

Page de 8
3
Operation
AUTO COOL
DRY
FAN
HEAT
2.Select operation mode
Press FAN button. For each press, fan speed changes
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
LOW
MED
HI
AUTO
1. Unit start
 Press ON/OFF on the remote controller, unit starts.
TEMP+
TEMP-
TEMP+ TEMP-
/
Base  Operation
Remote controller
   Air Flow Direction Adjustment
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote 
         memorize the previous 
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur 
adjusted to left or 
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency Operation:
temperature is below 16
o
C, do not use it in the 
Test operation:
Use this switch in the test operation when the room
normal operation.
 your finger from the switch: the cooling
Continue to press the test operation 
switch for more than 5 seconds. After
 you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
 Use this operation only when the remote controller
 is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which 
the start of this operation.
In this operation, the system automatically selects
the operation modes,cooling or fan or heat,
according to the room temperature.
.
It is not possible to operate in dry mode.
Room
temperature
Operation
   mode
Designated
temperature
Timer
mode
Air flow
ABOVE 23
O
C
BELOW 23
O
C
COOLING
HEAT
23
O
C
26
O
C
NO
NO
AUTOMATIC
AUTOMATIC
Pi
(C
ooling only uint)
Room  temperature
Operation
   mode
Designated
temperature
Timer
mode
Air flow
BELOW 23
O
C
FAN
26
O
C
NO
AUTOMATIC
Pi Pi
at air outlet if all vertical louvers are 
right.
mode ,
controller will automatically
Note:
set swing position.
means
as
Operation
Mode
AUTO
Display Board Remote
Controller
Note
COOL
DRY
HEAT
FAN
nothing
In DRY mode, when room temperature becomes
lower than temp.setting+2
o
C, unit will run 
intermittently at LOW speed regardless of FAN 
Under the mode of auto operation, air conditioner 
will automatically select Cool or Heat operation
according to room temperature. When FAN is set
to AUTO, the air conditioner automatically adjusts
temperature.
the fan speed according to room
In FAN operation mode , the unit will not operate in
COOL or HEAT mode  but only in FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled. In FAN mode, sleep operation 
setting.
is not available.