Sanyo CL4232 Manuel D’Utilisation

Page de 66
– 16 –
SM830078
(3)
Other Component Specifications
(B)
Outdoor Unit
MODEL No.
C4232
Compressor Motor Magnetic Contactor
FC - 2SUL
Coil rated
AC 240 V, 60 Hz
Coil resistance (at 68 
°
F)
Ω
350 
±
 10 %
Contact rated (Main)
AC 240 V, 35 A
Contact rated (Auxiliary)
AC 240 V, 3 A
Power Relay
HH62S
Coil rated
AC 240 V,  60 Hz
Coil resistance (at 77 
°
F)
k
Ω
17.2
Contact rated
AC 220 V, 5 A
Thermostat (Coil sensor)
YTB - 4U305F
Operating Temperature
°
F
79 
±
 3  OFF
75       ON
Contact rated
200 to 240 V, 1 A
+ 3
– 1
DATA SUBJECT TO CHANGE WITHOUT NOTICE
2. SPECIFICATIONS