eLeCTRICAL TROUBLeshOOTINg ChART - COOLINg
9k BTU, 12k BTU, & 18k BTU
NO COOLING OPERATION
Insure that Fuses 
are good and/or that 
Circuit Breakers are 
on and voltage is 208/230
Compressor and Fan 
Motor should now 
operate
See Refrigerant Circuit 
diagnosis if unit still is 
not cooling properly
Fan runs but 
Compressor doesn't
Compressor runs but 
Blower/Fan doesn't
Set thermostat to 
"Cool," and the Temp. 
below  the present 
Room Temp.
Nothing operates, 
entire system 
appears dead
Line voltage present 
at the Transformer 
Primary
24 Volts present at 
208/230 Volts present
at #1 relay on board? 
Y terminals on
t-stat and board?
Problems indicated with 
Room Thermostat or 
Control Wiring
Replace board 
Problems indicated 
in Blower Relay
of board
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
O.K.
O.K.
No
Is Line Voltage present 
at Motor Leads?
Check Capacitor, is 
Capacitor Good?
Replace Capacitor
Motor should run
Possible motor 
problem indicated.  
Check motor 
thoroughly
Yes
Yes
No
No
No
Supply Circuit 
problems, loose 
Connections, or bad 
Relays/Board
Replace Capacitor 
and/or Start Assist 
Device
Allow ample time 
for pressures to 
equalize
Possible Compressor 
problem indicated.  
See Compressor 
Checks
Is Locked Rotor
Voltage a minimum of 
197 Volts?
Are Capacitor and (if 
so equipped) Start 
Assist good?
Have System 
Pressures Equalized?
Compressor should 
run
Yes
Yes
No
No
No
No
Yes
Compressor and fan 
motor should now 
operate
See Refrigerant 
Circuit Diagnosis if 
unit still is not cooling 
properly
Yes
Yes
No
Check Supply Circuit’s 
jumper at transformer. If 
okay, replace board
24 Volts at
“R” Terminal on board
Before continuing 
check for Error 
Codes, see 
electronics control 
diagnostics and 
test mode, page 15
24V at t-stat and
control wiring?
Defective t-stat
defective control wiring
or transformer
Problems indicated with 
Control Transformer
replace board
31