Features and Benefits
Standard Features
• High Efficiency - High efficiency units reach as high as 
12.4 EER. Gas/electric units have electronic spark ignition 
and power vented combustion with steady state efficiencies 
of 80%. These efficiencies exceed all legislated minimum 
levels and provide low operating costs.
• Balanced Heating -
• Gas Heat - All gas heat units are built with two heating 
sections for two equal stages of capacity control. Each 
section includes a durable heat exchanger with 
aluminized steel or optional stainless steel tubes, a 
redundant gas valve, spark ignition, power venting, an 
ignition module for 100% shut-off and all of the safety 
controls required to meet the latest ANSI standards.
The gas supply piping can be routed into the heating 
compartment through a hole in the base pan of the unit 
or through a knockout in the piping panel on the front of 
the unit.
• Electric Heat - All electric heat models (factory installed 
only) are wired for a single power source and include a 
bank of nickel chromium elements mounted at the 
discharge of the supply air blower to provide a high velocity 
and uniform distribution of air across the heating elements. 
Every element is fully protected against excessive current 
and temperature by fuses and two thermal limit switches.
The power supply wiring can be routed into the control 
box through a threaded pipe connection in the base pan 
of the unit or through a knockout in the wiring panel on 
the front of the unit.
• BAS Controls - York’s Sunline™ series units offer factory 
mounted BAS controls such as Simplicity
®
 Intelli-
Comfort
, Novar, Honeywell, Johnson, York Commercial 
Comfort System (YCCS) and CPC.
• Convertible Airflow Design - All models (including those 
with an economizer) are suitable for either bottom or 
horizontal duct connections. Models with factory 
installed power exhaust are suitable for bottom duct 
connections 
only. For bottom duct, you remove the sheet 
metal panels from the supply and return air openings 
through the base of the unit. For horizontal duct, you 
replace the supply and return air panels on the rear of the 
unit with a side duct flange accessory.
• Factory Mounted Outdoor Air Dampers - All models are 
available with these "factory mounted" outdoor air damper 
options:
• Single enthalpy economizer with or without power 
exhaust
• BAS-ready economizer with or without power exhaust
• Motorized outdoor air damper
• Barometric Relief Damper
A fixed outdoor air intake assembly will be shipped in the 
return air compartment of all units ordered without an 
economizer or motorized outdoor air damper option. The 
assembly includes a rain hood with a damper that can be set 
for 10, 15 or 25% outdoor air. With bottom duct connections, 
the fixed outdoor air intake assembly should be mounted 
over the opening in the return air panel. With horizontal 
ductwork, it should be mounted on the return air duct.
• System Protection - Suction line freezestats are supplied 
on all units to protect against loss of charge and coil frosting 
when the economizer operates at low outdoor air 
temperatures while the compressors are running. Every unit 
has solid-core liquid line filter-driers and high and low-
pressure switches. Internal compressor protection is 
standard on all compressors. Crankcase heaters are 
standard on reciprocating compressors. Scroll compressors 
do not require crankcase heaters. Phase Monitors are 
standard on units with scroll compressors. This accessory 
monitors the incoming power to the unit and protects the 
unit from phase loss and reversed phase rotation.
• Advanced Controls - Simplicity™ ZJ/ZR/ZF control 
boards have standardized a number of features 
previously available only as options or by utilizing 
additional controls.
• Low Ambient - An integrated low-ambient control 
allows all units to operate in the cooling mode down to 
0
F outdoor ambient without additional assistance. 
Optionally, the control board can be programmed to 
lockout the compressors when the outdoor air 
temperature is low or when free cooling is available.
• Anti-Short Cycle Protection - To aid compressor life, 
an anti-short cycle delay is incorporated into the 
standard controls. Compressor reliability is further 
ensured by programmable minimum run times. For 
testing, the anti-short cycle delay can be temporarily 
overridden with the push of a button.
• Lead-Lag - An integrated Lead-Lag option allows equal 
run time hours on all compressors, thereby extending 
the life of all compressors. This option is selectable on 
the unit control board.
• Fan Delays - Fan on and fan off delays are fully 
programmable. Furthermore, the heating and cooling 
fan delay times are independent of one another. All units 
are programmed with default values based upon their 
configuration of cooling and heat.
• Safety Monitoring - The control board monitors the 
high and low-pressure switches, the freezestats, the gas 
The Simplicity® control board used in this product 
will effectively operate the cooling system down to 
0°F when this product is applied in a comfort cooling 
application for people. An economizer is typically 
included in this type of application. When applying 
this product for process cooling applications 
(computer rooms, switchgear, etc.), please 
reference applications bulletin AE-011-07 or call the 
applications department for Unitary Products @ 1-
877-UPG-SERV for guidance. Additional 
accessories may be needed for stable operation at 
temperatures below 30°F.