Carrier 52C Manuel D’Utilisation

Page de 52
3
UNIT DISASSEMBLY
This section includes common procedures for disas-
sembly and re-assembly of unit.  
TOOLS NEEDED
The following field-supplied items are recommended 
for general disassembly of the unit:
• Flat head screw driver
5
/
16
-in. nut driver
• Safety glasses
• Needle nose pliers
REMOVE FRONT PANEL
NOTE: Before removing front panel, remove 2 locking 
screws (if installed) located behind the filter handles. 
See Figure 3. If a lateral duct accessory is installed, the 
plenum must be removed before removing the front 
panel. Refer to Remove Lateral Duct Extension section 
for removal instructions.
1. Grasp the front panel firmly at the center of the 
top and bottom of the panel.
2. Pull the panel upward at the bottom and forward 
at the top to release magnetic latches and partition 
hooks. See Figure 4.
DISCONNECT POWER FOR 
CORD-CONNECTED UNIT
1. Turn selector switch to OFF position.
2. Open the disconnect switch at main power supply. 
Use proper Lockout and Tag procedures.
3. Unplug the unit service cord.
DISCONNECT POWER FOR 
PERMANENTLY CONNECTED 
(HARDWIRED) UNITS
1. Turn selector switch to OFF position.
2. Open the disconnect switch at main power supply. 
Use proper Lockout and Tag procedures.
3. Remove screw from access cover and remove 
access cover.
4. Pull out the plug assembly and disconnect. See 
Figure 5.
IMPORTANT: Follow manufacturer’s instruc-
tions when disassembling and re-assembling a 
unit for cleaning, maintenance, or part replace-
ment. When disassembling wiring, it is strongly 
recommended that numbered stickers be 
attached to identify leads and terminals to aid in 
the re-assembly process. Always review safety 
procedures prior to the start of a job.
Prior to servicing electrical equipment, discon-
nect all power to avoid electric shock! Tag all dis-
connects. Never alter cord or plug and do not use 
extension cords.
Electrical Data
3 –  230/208-v, 60 Hz
4 –  265-v, 60 Hz
Cooling Capacity (nominal)
07 –   7,000 Btuh
09 –   9,000 Btuh
12 – 12,000 Btuh
15 – 15,000 Btuh
52    PQ    A    3    12    3    0    1    AA
Series Designation
PTAC (Packaged Terminal Air Conditioner)
Non-Performance
Changes 0-9
Chassis Options
Blank or  AA – Standard
CP – Corrosion Protection
RC – Wall Thermostat Control
RP – Wall Thermostat Control with
Corrosion Protection
CE – Cooling with Electric Heat
CQ – Heat Pump with Electric Heat
PC – Cooling Only
PE – Cooling with Electric Heat
PQ – Heat Pump with Electric Heat
Packaging
1 –  Domestic
Latest Revision
A –  Z
Electric Heater Size
0 – No Heating (Cooling Only Model)
2 – 2.3 kW
3 – 3.4 kW
5 – 5.0 kW
FIGURE 2 — MODEL NUMBER NOMENCLATURE