Ariston 47-116-65 Manuel D’Utilisation

Page de 72
46
settings - adjustment - problem identifi cation menus
menu
sub
-menu
P
a
rameter
Description
value
default setting
6
3
DIAGNOSTICS
6
3
4
Zone 3 heat request
0 = OFF
1 = ON
8
SERVICE PARAMETERS
8
1
BOILER STATISTICS
8
1
0
Number of hours burner operating in heater mode (xxh/10)
8
1
1
Number of hours burner operating in hot water mode (xxh/10)
8
1
2
Number of fl ame separations (nr/10)
8
1
3
Number of ignition cycles (nr/10)
8
1
4
Average length of heating request (minutes)
8
2
BOILER
8
2
1
Fan Status
0 = OFF
 1 = ON
8
2
2
Fan speed (x100) rpm
8
2
3
Circulation pump speed
0 = OFF 
1 = Low speed
2 = High speed
8
2
4
Diverter valve position
0 = D.H.W. 
1 = Central Heating
8
2
5
D.H.W. Flow Rate (l/min)
8
2
8
Gas Power (kW)
8
3
BOILER TEMPERTURE
8
3
1
Heating fl ow temperature (in °C)
8
3
2
Heating backfl ow temperature (in °C)
8
4
SOLAR & STORAGE
8
4
2
Solar appliance water input temperature
activated only with the solar kit 
connected
8
5
SERVICE
8
5
0
Months to next maintenance
from 0 to 60 (month)
24
If setted the boiler will display that is time to call the installer for maintenance
8
5
1
Enable Maintenance advice
0 = OFF 
1 = ON
0
8
5
2
Maintenance Warning Reset
Reset? OK= Yes Esc = No
to erase the advice for maintenance
8
5
3
2nd Heat Exchanger Clogging State
0 =  DHW Exchanger OK
1 = Partially Clogged
2 = Very Clogged Please 
Replace
8
5
4
PCB hardware version
8
5
5
PCB software version
8
6
ERROR LIST
8
6
0
10 last errors
from E00 to E99
This parameter allows the last 10 boiler errors fl agged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from E00 to E99.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
8
6
1
Error list reset
Reset
OK = yes
ESC = no