Troubleshooting
Lockout
The AquaSmart will lock out if any number of abnormal 
conditions are detected.
HeatManager Technology
The Beckett AquaSmart comes equipped with the 
Department of Energy (DOE) 2012 compliant Heat 
Manager load-matching energy saving algorithm.  The 
Heat Manager saves fuel by dynamically changing the 
temperature high operating limit to the minimum 
temperature necessary to meet the heating demand.  
The qualifi ed service technician can adjust the 
HeatManager algorithm to maximize comfort or energy 
savings.
The HeatManager
TM
 algorithm is designed to operate the 
boiler at its lowest possible temperature while still 
meeting the heating demand.  By dynamically changing 
the boiler temperature, it is designed to reduce the 
energy used by the system without sacrifi cing comfort.  
The default HIGH effi ciency setting should work best for 
most systems.  However, there are many system factors 
that may have an effect on its ability to react to changes 
quickly enough and supply adequate heat, such as 
amount of connected radiation, boiler size, system 
design temperatures, etc.  The effi ciency setting adjusts 
how aggressively the HeatManager
TM
 algorithm attempts 
to reduce the boiler operating temperature.  If a loss of 
comfort is experienced, decreasing the effi ciency setting 
will help regain comfort at the expense of fuel savings 
(see section A of “Programming Additional Options” for 
instructions on changing the effi ciency setting).
Frozen Plumbing and 
Water Damage Hazard
If the residence is unattended in severely cold 
weather, boiler control safety lockout, heating 
system component failures, power outages or other 
electrical system failures could result in frozen 
plumbing and water damage in a matter of hours.
For protection, take preventative actions such as having 
a security system installed that operates during power 
outages, senses low temperature and initiates an 
effective action.  Consult your qualifi ed service 
technician or a home security agency.
Display Boiler Status Mode
KEY:
D - Current operating temperature mode of boiler. 
 
STANDBY will be displayed if neither the burner nor 
circulator are energized.  
CIRCULATING will be displayed if the circulator is 
energized but the burner is not.  
HEATING WTR will be displayed if a non-priority heat 
call has caused the burner to be energized.  
HEATING DHW will be displayed if a priority heat call 
has caused the burner to be energized.
FREEZE RES will be displayed if the burner has 
been running for 1 hour or the AquaSmart has been 
locked out for 1 hour.
E - Current boiler water temperature measurement
F - Adjusted high limit when economizing
G - Lockout reason (see Lockout section under 
Troubleshooting”.)


A
D
E


C
G
SENSOR ERR - The sensor has either detected an 
internal error or is not communicating properly with 
the AquaSmart.  The AquaSmart will not reset from 
this condition until it can detect a properly working 
sensor.
SELF-CHECK - An internal safety check, such as 
the check on the B1 relay contacts, has failed.  Hold 
ENTER (RESET) key for 5 seconds to reset from 
this condition.  If the error occurs again, replace the 
control.
CANCEL - The CANCEL (BACK) key was held for 
5 seconds or longer, which temporarily suspends 
the control’s operation.  The control will resume 
normal operation once the CANCEL (BACK) button 
is released.
1.
2.
3.


B
F
NOTE: When economizing, the display will toggle 
between screens A and B every 5 seconds.