T4800 INSTALLATION INSTRUCTIONS
G.  CONSTRUCTING  A  CHASE
Figure 20 - Chase Constructions
Figure 21 - Chase Assembly
1. Materials
a. The  chase  is  constructed  using  framing
materials  much  the  same  as  the  walls  in  your
home.  A  variety  of  materials  may  be  used
including brick, stone, veneer brick, or standard
siding  materials.
b. In  constructing  the  chase,  several  factors  must
be  considered:
1) Maintain a 2” air space around the chimney.
2) The  chase  top  must  be  constructed  of
noncombustible  material.
3) In cold climates, a firestop spacer should be
installed  in  an  insulated  false  ceiling  at  the
8’  level  above  the  fireplace  assembly. This
reduces  heat loss through the chase.
4) In  cold  climates,  the  walls  of  the  chase
should be insulated to the level of the false
ceiling as shown in Figure 21. This will help
reduce heat loss from the home around the
fireplace.
A  chase  is  a  vertical  boxlike  enclosure  built  around  the
chimney  and  fireplace. A  chase  may  be  constructed  for
the fireplace and chimney or for the chimney only. It is most
commonly constructed on an outside wall.
In  cold  climates,  it  is  recommended  that  the  chase  floor
be insulated using batt type insulation between the floor
joists.
Three examples of chase applications are shown in
Figure 20.
1. Fireplace and chimney enclosed in an exterior
chase.
2. Chimney offset through exterior wall and
enclosed  in  chase.
3. Chase constructed on roof.