Emerson SST2000 Manuel D’Utilisation

Page de 16
10
SER
SER
SER
SER
SERVICE INDICA
VICE INDICA
VICE INDICA
VICE INDICA
VICE INDICATION
TION
TION
TION
TION
SER
SER
SER
SER
SERVICE CHECKS
VICE CHECKS
VICE CHECKS
VICE CHECKS
VICE CHECKS
ON/OFF switch “ON”
Unit functioning Nor
Unit functioning Nor
Unit functioning Nor
Unit functioning Nor
Unit functioning Normall
mall
mall
mall
mally
y
y
y
y
Blower ON
Operating Light ON
ON/OFF switch “ON”
1.
1.
1.
1.
1.
P
P
P
P
Po
o
o
o
ow
w
w
w
wer is not being supplied to air c
er is not being supplied to air c
er is not being supplied to air c
er is not being supplied to air c
er is not being supplied to air cleaner
leaner
leaner
leaner
leaner.....
Blower ON
A. Check fuse or circuit breaker.
Operating Light OFF
B. Ensure power pack is properly installed and latched.
2.
2.
2.
2.
2.
Collecting cell shor
Collecting cell shor
Collecting cell shor
Collecting cell shor
Collecting cell shorted - 
ted - 
ted - 
ted - 
ted - T
T
T
T
Tur
ur
ur
ur
urn po
n po
n po
n po
n pow
w
w
w
wer Of
er Of
er Of
er Of
er Offffff  -  R
 -  R
 -  R
 -  R
 -  Remo
emo
emo
emo
emov
v
v
v
ve po
e po
e po
e po
e pow
w
w
w
wer pac
er pac
er pac
er pac
er pack - R
k - R
k - R
k - R
k - Remo
emo
emo
emo
emov
v
v
v
ve
e
e
e
e
 collecting cells - R
 collecting cells - R
 collecting cells - R
 collecting cells - R
 collecting cells - Re
e
e
e
eplace po
place po
place po
place po
place pow
w
w
w
wer pac
er pac
er pac
er pac
er pack - R
k - R
k - R
k - R
k - Restor
estor
estor
estor
estore po
e po
e po
e po
e pow
w
w
w
wer (ensur
er (ensur
er (ensur
er (ensur
er (ensure b
e b
e b
e b
e blo
lo
lo
lo
low
w
w
w
wer is
er is
er is
er is
er is
oper
oper
oper
oper
opera
a
a
a
ating).
ting).
ting).
ting).
ting).
A. If  Operating Light comes ON check cells for bent plates, loose ionizing
wire(s) or cracked insulator(s).
B. If  Operating Light remains OFF, malfunction is in the power pack. (See
power supply Checkout Procedure).
ON/OFF Switch “ON”
1.
1.
1.
1.
1. Air f
Air f
Air f
Air f
Air flo
lo
lo
lo
low sensor contamina
w sensor contamina
w sensor contamina
w sensor contamina
w sensor contaminated/misaligned
ted/misaligned
ted/misaligned
ted/misaligned
ted/misaligned
Blower OFF
A. Remove power pack and clear contamination inside black bushing around
Operating Light ON
the small sensor element.
B. Ensure small sensor element is centered in bushing.
2.
2.
2.
2.
2. Air sensor left in b
Air sensor left in b
Air sensor left in b
Air sensor left in b
Air sensor left in bypassed condition after ser
ypassed condition after ser
ypassed condition after ser
ypassed condition after ser
ypassed condition after servicing
vicing
vicing
vicing
vicing.**
.**
.**
.**
.**
3.
3.
3.
3.
3. F
F
F
F
Faulty air f
aulty air f
aulty air f
aulty air f
aulty air flo
lo
lo
lo
low sensor panel.
w sensor panel.
w sensor panel.
w sensor panel.
w sensor panel.
Excessive arcing during
1.
1.
1.
1.
1. W
W
W
W
Wet collecting cell.
et collecting cell.
et collecting cell.
et collecting cell.
et collecting cell.
normal operation -
A. Allow cell(s) to dry after cleaning before applying power.
Operating Light may blink
2.
2.
2.
2.
2. Dama
Dama
Dama
Dama
Damag
g
g
g
ged collecting cell(s).
ed collecting cell(s).
ed collecting cell(s).
ed collecting cell(s).
ed collecting cell(s).
A. Remove cell(s) and inspect for bent plates, loose ionizing wire(s), cracked
insulator(s), etc.
3.
3.
3.
3.
3. Collecting cells dir
Collecting cells dir
Collecting cells dir
Collecting cells dir
Collecting cells dirty
ty
ty
ty
ty.....
A. Clean cells as instructed in this manual.
4.
4.
4.
4.
4. F
F
F
F
Faulty po
aulty po
aulty po
aulty po
aulty pow
w
w
w
wer suppl
er suppl
er suppl
er suppl
er supply (see po
y (see po
y (see po
y (see po
y (see pow
w
w
w
wer suppl
er suppl
er suppl
er suppl
er supply c
y c
y c
y c
y chec
hec
hec
hec
heck
k
k
k
kout pr
out pr
out pr
out pr
out procedur
ocedur
ocedur
ocedur
ocedure)
e)
e)
e)
e)
**NO
**NO
**NO
**NO
**NOTE:
TE:
TE:
TE:
TE: Your air cleaner may be equipped with an air flow sensor (switch) which turns the unit ON and OFF in
response to the system blower. It may have been “wired out” during a service check and inadvertently left in this
condition.
B
B
B
B
BASIC SST SER
ASIC SST SER
ASIC SST SER
ASIC SST SER
ASIC SST SERVICE GUIDE
VICE GUIDE
VICE GUIDE
VICE GUIDE
VICE GUIDE
This guide will cover most homeowner complaints. If, after checking the items listed, the unit still fails to operate