5
CSDV Series Direct Vent Gas Stove
pRODUCT FEATURES  
pRODUCT SpECIFICATIONS
  This  appliance  has  been  certified  for  use  with  either 
natural or propane gas. See appropriate data plates.
  This appliance is not for use with solid fuels.
  The appliance is approved for bedroom or bedsitting 
room installations.
  The appliance must be installed in accordance with local 
codes if any. If none exist use the current installation 
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in 
Canada.
  This appliance is mobile home approved.
  The appliance must be properly connected to a venting 
system.
  The appliance is not approved for closet or recessed 
installations.
  For alcove installation see “Clearances,” Page 9. 
ON
OF
F
FP2724
CSDV controls
Pilot 
Optional 
Remote 
Receiver 
Door
Figure 1 - 
CSDV Cast Iron Stove Controls
Hi/Lo Knob 
On/Off 
Switch 
Optional Blower 
Ignitor Box 
Located Under 
Right Front Leg  
FP2724
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certi-
fied  without  deration  for  elevations  up  to  4,500  feet 
(1,370 m) above sea level.
For  elevations  above  4,500  feet  (1,370  m)  in  USA, 
installations  must  be  in  accordance  with  the  current 
ANSI  Z223.1/NFPA  54  and/or  local  codes  having 
jurisdiction.
In  Canada,  please  consult  provincial  and/or  local 
authorities having jurisdiction for installations at eleva-
tions above 4,500 feet (1,370 m).
GAS pRESSURES
   
Natural 
Propane (LP)
  Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
10.5” w.c. 
13.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
    
 
max.Input  min. Input 
  model 
Fuel 
BTU/h 
BTU/h 
Orifice Size
  CSDV20NV  Nat. 
18.000 
12,500 
#43
  CSDV20PV 
LP 
19,000 
15,000 
#54
  CSDV30NV  Nat. 
28,000 
17,000 
#35
  CSDV30PV 
LP 
28,000 
21,000 
#51
    
 
 
 
Front  Rear
  CSDV40NV  Nat. 
33,000 
26,000 
#46 
#43
  CSDV40PV 
LP 
33,000 
30,000 
#57  1.45 mm
GAS SpECIFICATIONS & ORIFICE SIZE