Monessen Hearth CSDV20DNV Manuel D’Utilisation

Page de 44
8
58D6056
CSDV Series Direct Vent Gas Stove
W
ARNING
CLEARANCES
CLEARANCES TO COmBUSTIBLES 
The dimensions shown in Figures 4 and 5 are minimum clearances to maintain 
in installing this heater. Left and right clearances are determined when facing 
the front of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow 
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material 
other than wood flooring. If installed on carpet or vinyl flooring, the appliance 
shall be installed on a metal, wood or noncombustible material panel extending 
full width and depth of the appliance.
A
E
Minimum
D
Minimum
to Either
Side Wall
ST1128
sidewall clearance
Ceiling
Mantel
Side 
Wall
Side 
Wall
ST1128
Front View
B
C
F
Minimum
36” (914 mm)
in Front
St1129
mantel clearances
Ceiling
Side View
ST1129
G
G
ST1130
corner clearance
Corner 
Installation
ST1130
Minimum
D
Minimum
to Either
Side Wall
ST1131
sidewall clearance
Wall Installation
ST1131
 
mantel Clearance from 
 
 
Corner  
 
Top of Unit 
Side measured from Top 
Rear 
measured
 
 
min. Ceiling 
max 
 
 
 
measured 
From Top 
 
 
from Floor 
protrusion 
Height 
Right 
Left 
From Back 
Corners
 
 product 
G
 
CSDV20 
72" (1829 mm)  12" (305 mm) 
22" (559 mm)  4" (102 mm) 
4" (102 mm) 
1" (25 mm)  1/2" (13 mm)
 
CSDV30 
72" (1829 mm)  12" (305 mm) 
34" (864 mm)  4" (102 mm) 
4" (102 mm) 
1" (25 mm)  1/2" (13 mm)
 
CSDV40 
72" (1829 mm)  12" (305 mm) 
34" (864 mm)  4" (102 mm) 
4" (102 mm) 
1" (25 mm)  1/2" (13 mm)
Figure 4 - 
Minimum Clearances 
to Walls and Ceiling