4.     Remove adhesive backing from plastic clip. Press 
clip to bottom of valve. Clip thermo bulb into plastic 
clip. See Figure 10. 
5.     Reattach faceplate or reinstall base.
6.     Install knob to shaft of t-stat sensor. See Figure 9, 
page 14.
Figure 10 - Clipping Thermo Bulb into 
Plastic Clip. 
Valve 
Thermo 
Bulb
Plastic Clip 
OPERATION OF THERMOSTAT SENSOR
1.     Follow millivolt lighting instructions on lighting plate attached to unit or in homeowner’s manual. 
2.     With control knob in the “ON” position make sure the ON/OFF switch is in the “OFF” position. See Figure 11. 
3.     The unit is now being controlled by the thermostat sensor. The sensor will now cycle the burners on and off. You can 
adjust how often the unit cycles by turning the control knob on the sensor. 
Figure 11 - Control Knob in “ON” Position and ON/OFF Switch in “OFF” Position 
Control 
Knob
T-Stat 
Sensor 
ON/OFF 
Switch 
ELECTRICAL WIRING (MILLI-VOLT)