Lopi Liberty Wood Stove Manuel D’Utilisation

Page de 38
14
Stove Installation 
(for qualified installers only)
© Travis Industries
100-01164
4041115
Standard Ceiling
with a Factory
Built Chimney
A
A
A
A
Chimney Cap
(See the section "Chimney 
Termination Requirements" 
for more details)
A
A
AA
AA
A
A
AA
AA
AA
AA
AA
AA
AAAAA
Chimney Sections
Minimum Air Space to 
Combustibles (See 
Chimney Manufacturer's 
Instructions - usually 2")
Chimney Connector Sections
Follow the chimney 
manufacturer's instructions 
and clearances for roof 
penetrations.  A storm collar 
and flashing are required 
(some require a radiation 
shield).
}
}
Minimum 15' 
Maximum 33'
Stove Clearances
(See the section "Stove 
Placement Requirements" 
for more details)
Floor Protection
(See the section "Floor 
Protection Requirements" 
for more details)
Follow the chimney 
manufacturer's instructions 
and clearances for floor 
penetrations.  A ceiling 
support is required, an attic 
insulation shield is required 
where insulation is present.
Insulation
Figure 10
Cathedral Ceiling
with a Factory
Built Chimney
A
A
A
A
Chimney Cap
(See the section "Chimney 
Termination Requirements" 
for more details)
A
A
AA
AA
A
A
AAAAA
AAAAA
Chimney Sections
Minimum Air Space to 
Combustibles (See Chimney 
Manufacturer's Instructions - 
usually 2")
Follow the chimney 
manufacturer's instructions 
and clearances for roof 
penetrations.  A storm 
collar, flashing, and 
cathedral-style chimney 
support are required 
(some require a radiation 
shield).
}
Minimum 15' 
Maximum 33'
Stove Clearances
(See the section "Stove 
Placement Requirements" 
for more details)
Floor Protection
(See the section "Floor 
Protection Requirements" 
for more details)
Chimney 
Connector 
Sections
Figure 11