OpERATING INSTRUCTIONS
LIGHTING pILOT FOR THE FIRST TImE  
W
ARNING
Never use an open flame to check 
for gas leaks.
INITIAL LIGHTING 
Purge air from the supply line as follows: 
•  Open main shutoff valve.
•  Unscrew main pressure test point.
•  Leave  inlet  test  screw  open  until  gas 
comes in.
•  When gas is flowing, tighten inlet screw 
immediately.
W
ARNING
If using a soap and water solutiong 
to  test  for  leaks,  DO  NOT  spray 
solution onto control body.
LEAK TESTING 
You may check for gas leaks with the following 
methods only:
•  Soap and water solution
•  An approved leak testing spray
•  Electronic sniffer
Check for gas leaks in each of the following locations:
•  Pipe from the gas supply line connection to the gas valve
•  Burner connections  
•  Field made joints / gas shutoff valve 
•  Pilot  
•  Factory made joints
•  Each joint or connection 
•  All joints on valve and control body
1.  Depress and turn knob counterclockwise 
 
to pilot position. 
2.  Depress  fully  and  hold  pilot  gas  knob.  The 
electronic  ignitor  will  automatically  ignite  the 
pilot. Keep knob fully depressed for a few sec-
onds. Release and check that pilot continues 
to burn. 
If the pilot does not stay lit, repeat Steps 1 and 2. 
Figure 42 - 
Pilot Position 
LIGHTING pILOT  
PILOT
OF
   
   
 P
IL
O
    ON
FP1935
control knob pilot
The control has an interlock device that does not allow the lighting of the 
stove up to the moment the safety device of the flame has not  interrupted 
the gas flow. After that period of time (when the magnet is closed), it is 
possible to start the lighting operation. 
The gas control knob is designed to be operated by hand. DO NOT use 
any tools during this operation. Damaged knobs may result in serious 
injury. 
W
ARNING