Monessen Hearth CSDV20SNV Manuel D’Utilisation

Page de 44
58D6056
21
CSDV Series Direct Vent Gas Stove
VENTING INSTALLATION 
H
V
V
1
ST1146
vert vent 2 elbows
N O T E :   I n s t a l l 
restrictor  into  4" 
collar  of  stove  or 
first  vent  section 
as shown.  
Table 6 - Venting with Two (2) 90° Elbows
 
maximum 
minimum 
minimum 
minimum 
  Horizontal (H)  CSDV20 (V)  CSDV30 (V)  CSDV40 (V)
 
24"  
41Z\v"  
44C\v" 
48C\v" 
 
 
(610 mm) 
(1048 mm) 
(1137 mm) 
(1238 mm)
 
20' 
95Z\v" 
98C\v" 
102Z\v" 
 
 
(6 m) 
(2419 mm) 
(2508 mm) 
(2597 mm)
Figure 30 - 
Vertical Rigid Venting 
Configuration using Two (2) 90° 
Elbows
NOTE: Vertical (V) 
+ Vertical (V
1
) = 20'  
(6 m) Maximum
V
ST1147
vert vent
NOTE:  Install  restrictor 
into  4"  collar  of  stove 
or  first  vent  section  as 
shown.  
Figure 31 - 
Vertical Rigid Venting Configuration with 
No Horizontal Run
ST1147
Vertical 
Venting (V) 
= 40' (12 m) 
Maximum
SImpSON DURAVENT GS 4" x 6B\," (BLACK pIpE)
 
Number 
Description
 
902B 
6B\," x 48" Pipe
 
903B 
6B\," x 36" Pipe
 
904B 
6B\," x 24" Pipe
 
906B 
6B\," x 12" Pipe
 
907b 
6B\," x 9" Pipe
 
908B 
6B\," x 6' Pipe
 
911B 
6B\," Adjustable (11" - 14B\," Pipe)
 
940 
Wall Thimble
 
941 
Cathedral Ceiling Support Box
 
943 
Roof Flashing 0/12 - 6/12
 
943S 
Roof Flashing 7/12 - 12/12
 
945B 
6B\," x 45° Elbow
 
950 
Vinyl Siding Standoff
 
953 
Storm Collar
 
963 
Ceiling Firestop
 
981 
36" Snorkel Termination
 
984 
Horizontal Termination Vent Cap
 
988 
Wall Strap
 
990B 
6B\," x 90° Elbow
 
991 
Vertical High Wind Termination
 
Number 
Description